Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
National Instruments Manuals
Controller
AT-GPIB/TNT
Getting started
Table 2-2. Possible Base I/O Address Switch Settings For At-Gpib/Tnt - National Instruments AT-GPIB/TNT Getting Started
For windows 98/95
Hide thumbs
Also See for AT-GPIB/TNT
:
Getting started
(60 pages)
,
Getting started
(42 pages)
,
Getting started
(40 pages)
National Instruments
AT-GPIB/TNT
Getting Started
1
2
3
4
5
Table Of Contents
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
page
of
64
Go
/
64
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Chapter 2
Installation and Configuration
AT-GPIB/TNT for Windows 98/95
Follow these steps to reconfigure the base I/O address of the
AT-GPIB/TNT:
1. Locate the base I/O address switch at SW1 on your AT-GPIB/TNT
board. Refer to the parts locator diagram, Figure 2-5.
2. Change the switch settings to configure the GPIB board to match
the base I/O address of the Input/Output Range assigned by
Windows.
Press down on the side marked OFF to select a binary value of 1 for
the corresponding address bit. Press down on the ON side of the
switch to select a binary value of 0. Refer to Figure 2-6 for an
example of the switch settings and corresponding base I/O
addresses. Table 2-2 shows the possible switch settings, the
corresponding base I/O addresses, and the I/O address space used
for each setting. The default settings are in bold italics.
Table 2-2. Possible Base I/O Address Switch Settings for AT-GPIB/TNT
Switch Setting
A9
A8
A7
0
1
0
0
1
0
0
1
0
0
1
0
0
1
1
0
1
1
0
1
1
0
1
1
1
0
0
1
0
0
1
0
0
1
0
0
Base I/O
A6
A5
Address (hex)
0
0
100
0
1
120
1
0
140
1
1
160
0
0
180
0
1
1A0
1
0
1C0
1
1
1E0
0
0
200
0
1
220
1
0
240
1
1
260
2-8
I/O Address
Space Used (hex)
100 to 11F
120 to 13F
140 to 15F
160 to 17F
180 to 19F
1A0 to 1BF
1C0 to 1DF
1E0 to 1FF
200 to 21F
220 to 23F
240 to 25F
260 to 27F
© National Instruments Corporation
Table of
Contents
Previous
Page
Next
Page
1
...
22
23
24
25
26
27
28
29
Advertisement
Table of Contents
Troubleshooting
Troubleshooting and Common Questions
45
EDVR Error Condition with ibcntl Set to 0xE0320029 (-533594071) or
46
Troubleshooting Diagnostic Utility Failures
49
Related Manuals for National Instruments AT-GPIB/TNT
Controller National Instruments AT-GPIB/TNT Getting Started
With ni-488.2 software for dos graphics applications (60 pages)
Computer Hardware National Instruments AT-GPIB/TNT Getting Started
(59 pages)
Computer Hardware National Instruments AT-GPIB/TNT Getting Started
(45 pages)
Computer Hardware National Instruments AT-GPIB/TNT Getting Started
Ni-488.2m software for lynxos (42 pages)
Computer Hardware National Instruments AT-GPIB/TNT Getting Started
With ni-488.2 software for dos (40 pages)
Controller National Instruments AT-GPIB Getting Started
Ni-488m software for interactive unix system v (53 pages)
Controller National Instruments GPIB PCI-GPIB Getting Started
And the ni-488.2m software for solaris 2 (31 pages)
Controller National Instruments PCI-GPIB Installation Manual
For solaris (17 pages)
Controller National Instruments GPIB Series Getting Started
(34 pages)
Controller National Instruments PXI NI PXI-8105 User Manual
Embedded controller kit (73 pages)
Controller National Instruments IC-3121 User Manual
Industrial controller (33 pages)
Controller National Instruments GPIB-232CT User Manual
Microgpib rs-232 to ieee-488 controller (216 pages)
Controller National Instruments PXI 8351 User Manual
(117 pages)
Controller National Instruments PXIe-8861 User Manual
(22 pages)
Controller National Instruments CompactRIO cRIO-9072 User Manual And Specifications
Reconfigurable embedded chassis with integrated intelligent realtime controller for compactrio (27 pages)
Controller National Instruments CompactRIO sbRIO-9603 Hardware Installation Manual
Single-board controller with ni-daqmx (60 pages)
Related Content for National Instruments AT-GPIB/TNT
AT-GPIB/TNT Table A-1. Possible Base I/O Address Switch Settings
National Instruments AT-GPIB/TNT
AT-GPIB Figure 3-2. Base I/O Address Switch Settings
National Instruments AT-GPIB
GPIB-232 Table 3-4. Gpib Address Switch Settings For G Mode
National Instruments GPIB-232
NI PXI-8109 Current Hardware Switch Settings
National Instruments NI PXI-8109
NI-488.2M Figure 7-2. Board Configuration For An At-Gpib Interface Board
National Instruments NI-488.2M
GPIB-SCSI-A Configuration Switch Settings For Sw1
National Instruments GPIB-SCSI-A
GPIB-232CT Figure 3-1. S Mode Switch Settings
National Instruments GPIB-232CT
GPIB-232CT-A Primary Gpib Address
National Instruments GPIB-232CT-A
GPIB-1284CT Step 4. Switch On The Gpib-1284Ct
National Instruments GPIB-1284CT
GPIB-ENET Series Figure 2-1. Default Mode Switch Settings (All Switches Off)
National Instruments GPIB-ENET Series
PXI Series Current Hardware Switch Settings
National Instruments PXI Series
GPIB-ENET Table B-1. Dip Switch Settings For Modes Of Operation
National Instruments GPIB-ENET
GPIB-ENET Dip Switch Settings For Modes Of Operation
National Instruments GPIB-ENET
GPIB Series S Mode Switch Settings For Baud Rate
National Instruments GPIB Series
DAQ-STC Series Table B-2. Registers In Order Of Address*
National Instruments DAQ-STC Series
NI PXIe-8880 Current Hardware Switch Settings
National Instruments NI PXIe-8880
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL