15) After the oxygen receiver pressurizes and the oxygen generator enters the
standby mode, adjust the pressure regulator at the outlet of the oxygen
receiver until the pressure of the product oxygen meets the needs of your
application.
6.2
Operation
The oxygen generator can be operated in auto or manual mode depending on the
requirements of your application. To use product oxygen that meets the
specifications for your model listed in the Appendix A of this instruction manual, set
the AUTO/MANUAL switch to AUTO to produce oxygen only during times of the
oxygen demand.
6.3

Shutdown

1)
Stop the flow of product oxygen from the oxygen receiver to your application
by fully closing all manual valves between the outlet of the oxygen receiver
and the inlet to your application.
Make sure the AUTO/MANUAL switch on the control panel is set to AUTO.
2)
3)
Allow the oxygen receiver to repressurize fully. When the oxygen receiver
repressurizes, after a time delay of five cycles, the oxygen generator stops
cycling and the yellow indicator light on the AUTO/MANUAL switch shuts off.
Set the ON/OFF switch on the control panel to OFF.
4)
Set the AUTO/MANUAL switch on the control panel to MANUAL.
5)
6.4

Normal Start-up

1)
Provide feed air that meets the specification for your model to the oxygen
generator. Make sure the FEED AIR PRESSURE gauge on the control panel
AS-A—AS-P Series Instruction Manual
Allow the oxygen generator to enter standby during shutdown
to ensure that the oxygen receiver contains oxygen at design
purity during the subsequent restart and also ensure that the
unit shuts down at the proper point in the cycle. Failure to wait
until the oxygen generator enters standby results in temporarily
reduced purity oxygen during the subsequent restart.
To perform a normal start-up, the oxygen generator first
requires a shutdown as described in Section 6.3 — Shutdown.
If the oxygen generator shuts down due to a power loss, follow
the procedure in Section 6.1 — Initial Start-Up to restart the
oxygen generator.