Introduction; Intended Use; Features; Package Contents - Parkside PGS 500 A1 Original Instructions Manual

Die grinder
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
DIE GRINDER PGS 500 A1

Introduction

Congratulations on the purchase of your new appli-
ance. You have chosen a high-quality product. The
operating instructions are part of this product. They
contain important information about safety, usage
and disposal. Before using the product, please famil-
iarise yourself with all operating and safety instruc-
tions. Use the product only as described and for the
range of applications specified. Please also pass
these operating instructions on to any future owner.

Intended use

The appliance is intended for grinding and deburr-
ing metal with aluminous abrasives and work with
sanding belt bodies. It is furthermore intended for
brushing and polishing metal. Any other use of or
modification of the appliance is deemed contrary
to the intended use and carries the risk of serious
personal injury. Not for commercial use.

Features

Steplessly adjustable speed control
ON/OFF switch
Power cord
Ventilation slits
Tensioning nut
Collect chuck 6 mm (pre-assembled)
Spindle lock button
Collect chuck 3.2 mm
Grinding stone
Assembly wrench
GB │ IE
14 

Package contents

1 die grinder PGS 500 A1
2 collet chucks
1 grinding stone
1 assembly wrench
1 plastic case
1 set of operating instructions

Technical data

Rated power consumption 500 W
Rated voltage
Rated speed
Chuck suspension
Intended shaft diameter
Clamping
Protection class
NOTE
Only use accessories designed for more
than 30,000 rpm.
Noise emission value
Noise measurement value determined in
accordance with EN 60745. The noise level of the
power tool rated A is typically the following:
Sound pressure level
Uncertainty K
Sound power level
Uncertainty K
Wear hearing protection!
Vibration emission value
Total vibration values (vector total of three directions)
determined in accordance with EN 60745
Vibration emission value
Uncertainty
230 V ~ , 50 Hz (AC)
n 4,500–30,000 min
-1
max. Ø 6 mm
max. Ø 6 mm
min. 10 mm
II /
(double insulation)
L
= 78.4 dB (A)
PA
K
=
3
dB
PA
L
= 89.4 dB (A)
WA
K
=
3
dB
WA
a
= 5.301 m/s
h
K = 1.5 m/s
PGS 500 A1
2
2