Electrical Characteristics - Basler Ace User Manual

Prototype usb 3.0 cameras
Hide thumbs Also See for Ace:
Table of Contents

Advertisement

Physical Interface
The following voltage requirements apply to a direct-coupled GPIO line when it is set as an
output and when it is in the "off" state:
Voltage
+30.0 VDC
+3.3 to +24 VDC
< +3.3 VDC
Table 7: Voltage Requirements for a Direct-coupled GPIO Line Set as an Output
The following applies to a direct-coupled GPIO line when it s set as an output and when it is in
the "on" state:
Use a pull up resistor to account for the fact that the camera uses an open collector GPIO
output. The residual voltage will typically be approximately 0.4 V at 50 mA and 25 °C housing
temperature.
The actual residual voltage, however, depends on camera operating temperature, load current,
and production spread.
Note: The maximum current allowed through the output circuit is 50 mA.
5.9.4.2

Electrical Characteristics

As shown in Figure 22, shows the applicable electrical circuit when a GPIO line is set to operate as
an output. The figure is drawn to specifically apply to pin 1 (Line 3) as an example but, with the
necessary modifications, it equally applies to pin 3 (Line 4).
40
Significance
Absolute maximum; the camera can be damaged if the absolute maximum is
exceeded.
Recommended direct-coupled GPIO output supply voltage range.
The direct-coupled GPIO output can operate erratically.
AW00123401000