4.4

Adjustment procedure

4.4.1

Analog output signal voltage/current switchover (Pr.309) setting

Use Pr.309 Analog output signal voltage/current switchover to select whether to send the same signal from terminal AM0
(voltage output) and terminal AM1 (current output), or to send the signals separately.
Pr.309
Description
setting
value
0
(Initial
Outputs the same selection signal from
value)
both the voltage output terminal (AM0)
and the current output terminal (AM1).
The signal that set in Pr.306 Analog
output signal selection is enabled. (The
Pr.310 setting is disabled.)
10
Terminal
Parameter setting
Pr.306: Selects the output signal.
AM0
Pr.307: Output signal value when analog output is
zero.
AM1
Pr.308: Output signal value when analog output is at
maximum.
Pr.306: Selects the output signal.
AM0
Pr.307: Analog output value when output signal is
zero.
AM1
Pr.308: Analog output value when output signal is at
maximum.
Calibration
parameter
Pr.323
Pr.324
C1 (Pr.901)