Pr.309
Description
setting
value
1
Outputs separate selection signals from
the voltage output terminal (AM0) and the
current output terminal (AM1).
11
NOTE
• "Analog output" means the voltage (0 to ±10 V) and current (0 to 20 mA) output from terminals AM0 and AM1; while "output
signal" indicates the monitor signal (refer to
28
ANALOG OUTPUT
Terminal
Pr.310: Selects the output signal.
Pr.311: Output signal value when analog output is
AM0
zero.
Pr.312: Output signal value when analog output is at
maximum.
Pr.306: Selects the output signal.
Pr.307: Output signal value when analog output is
AM1
zero.
Pr.308: Output signal value when analog output is at
maximum.
Pr.310: Selects the output signal.
Pr.311: Analog output value when output signal is
AM0
zero.
Pr.312: Analog output value when output signal is at
maximum.
Pr.306: Selects the output signal.
Pr.307: Analog output value when output signal is
AM1
zero.
Pr.308: Analog output value when output signal is at
maximum.
page
31) set in parameters Pr.306 and Pr.310.
Parameter setting
Calibration
parameter
Pr.323
C0 (Pr.900)
Pr.324
C1 (Pr.901)
Pr.323
C0 (Pr.900)
Pr.324
C1 (Pr.901)