Pentair KEYSTONE OM3 Installation And Maintenance Instructions Manual

Pentair KEYSTONE OM3 Installation And Maintenance Instructions Manual

Epi-2 local interface module

Advertisement

Quick Links

Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE
InstallatIon and MaIntenance InstructIons
Index
1 Optional module 3:
Local Interface module .................................. 1
2 Installation ...................................................... 2
4 to locally operate the actuator ...................... 4
5 OM3 wiring diagram ....................................... 5
6 Identification.................................................... 6
7 Safety instructions .......................................... 7
8 Installation ...................................................... 8
9 Special maintenance ...................................... 8
The present IOM has to be considered
integral part of the IOM for the basic EPI-2,
doc. ref. VCIOM-02881.
1. OPtIOnaL MOduLE 3:

LOcaL IntErfacE MOduLE

1.1 LocaL Interface functIonaLIty
the OM3 Local Interface module is supplied as
an option on Keystone EPI-2 actuators and fits
all models.
It is possible to receive the actuator already
equipped with the OM3 if ordered together with
the basic version. alternatively, only for the
water proof version, it is possible to order the
OM3 as a separate kit to be installed afterwards
on the basic actuator.
the subsequent retrofitting of the OM3 on
existing EPI-2 is not allowed in the explosion
proof version.
the OM3 is an optional module allowing
local control with the following additional
functionalities:
www.pentair.com/valves
• Selection of Local/Remote actuator
control through the selector (lockable in
both positions).
• Open/Close command through the non
intrusive push-buttons.
• Actuator position indication by means
of 2 LEds.
IMportant
For decommissioning instructions, please refer
to the relevant chapter in the EPI-2 manual
ref. VCIOM-02881.
WarnIng
EPI-2 actuator must be electrically isolated before
any disassembling and reassembling operations.
Before any disassembling or reassembling
operations, please follow in detail the relevant
paragraph of the basic installation and operating
manual (latest revision available).
WarnIng
The electronic parts of the EPI-2 actuators
and all optional modules can be damaged by a
discharge of static electricity. Before you start,
touch a grounded metal surface to discharge
any static electricity.
WarnIng
EPI-2 actuators can be operated through a
Bluetooth™ PDA or PC with the following
configuration:
• The commands are enabled by Bluetooth,
only when the BT control is active.
When operating with Bluetooth™, the controls
via PDA or PC have priority on any other remote
commands and allow full actuator operability
from a distance also when the valve is not
visible. Special attention must be paid under
this condition to avoid any damages or injuries
to people working close to the valve. Keystone
will not accept any responsibility for damages
or injuries caused by an improper use of your
Bluetooth™ PDA or PC.
© 2012 Pentair plc. all rights reserved.
WarnIng
It is assumed that the installation, configuration,
commissioning, maintenance and repair works
are carried out by qualified personnel and
checked by responsible specialists.
WarnIng
Repair work, other than operations outlined in this
manual, is strictly reserved to qualified Pentair
personnel or to personnel authorized by the
company itself.
1.2 Manufacturer
Manufacturer with respect to Machinery
directive 2006/42/Ec: Biffi Italia as specified
on the actuator label.
VcIoM-01496-en 15/02

Advertisement

Table of Contents
loading

Summary of Contents for Pentair KEYSTONE OM3

  • Page 1: Table Of Contents

    Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons Index WarnIng • Selection of Local/Remote actuator control through the selector (lockable in It is assumed that the installation, configuration, commissioning, maintenance and repair works 1 Optional module 3: both positions).
  • Page 2: Installation

    Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons 2. InStaLLatIOn to assemble the OM3 Local Interface module onto the EPI-2 actuator, proceed as follows: • Ensure that all the parts received with the OM3 are available (see figure 1): pos.
  • Page 3 Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons • Connect the Local Interface module to the ground stud by screwing the ‘ground kit’ (screw + toothed washer). Grounding the Local Interface fIgures 6/6a - • Take the 4 screws for connecting the Local Interface black connector to the terminal board, in pos.
  • Page 4: Description Of Om3 Local Interface

    Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons pos. description 2-position lockable selector switch OPEn push-button cLOSE push-button OPEn position and correct with maneuver indicating LEd (default green color) cLOSE position and correct with maneuver indicating LEd (default red color) 3.
  • Page 5: Om3 Wiring Diagram

    Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons 5. OM3 WIRING dIAGRAM CLC1 CLC2 OPC1 OPC2 36 32 33 34 20 21 22 23 24 25 26 27 28 29 30 31 (note 1) remote commands (note 6)
  • Page 6: Identification

    Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons 6. IdEntIfIcatIOn • IP 66/68. • NEMA 4/4X/6 according to NEMA 250. 6.1 Water-, dust-proof VersIon 6.2 LabeL for appLIcatIon In Water-, dust-proof areas EPI-2 actuators with OM3 are designed and manufactured according to En 60529 standards.
  • Page 7: Safety Instructions

    Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE InstallatIon and MaIntenance InstructIons 7. SafEtY InStructIOnS WarnIng Installation in ambient with the presence of 7.1 foreWord explosive atmospheres not covered by the specified grade of protection specified in the label, this section is an integration of the base...
  • Page 8: Installation

    Pentair trademarks and logos are owned by Pentair plc. all other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice.

Table of Contents