Download Print this page

Waterco ECO-V 150 Owners & Installation Manual page 24

Hide thumbs Also See for ECO-V 150:

Advertisement

month. It is also important to keep this area free of large debris such as leaves,
branches, mulch, plastic bags, etc.
12 FAULT Status
Warning: While the FAULT LED is illuminated the motor will not run, upon clearing
the fault, the motor may automatically resume running depending on where in the
schedule the FAULT occurred. This may cause personal injury or damage to the
equipment.
The paragraphs below illustrate the possible faults that can occur with the Waterco
ECO-V 150. If the Waterco ECO-V 150 does not restart automatically following the
FAULT, cycle ac power to the Waterco ECO-V 150 and wait five (5) minutes.
The Waterco ECO-V 150 reads the FAULT status and provides feedback to the user
via the FAULT LED. The Waterco ECO-V 150 will illuminate the FAULTLED when a
FAULT is present. The Waterco ECO-V 150 will stop and remain OFF when the
FAULT is present. Once the FAULT is cleared, if the Waterco ECO-V 150 was
previously running, it will automatically resume running the normal schedule.
Refer Joey re chart image
Below is the behaviour of the FAULT LED when a FAULT is detected:
1. When a FAULT is present, and the motor is not running, only the FAULT LED and
power LED will illuminate.
2. When a FAULT is present, and the motor is running, then the FAULT LED will
illuminate. During the FAULT condition, the bar graph LEDs on the interface will turn
OFF. However, the power LED, start LED & active STEP LED will remain
illuminated.

Hide quick links:

Advertisement