Table of Contents
LOCATION ---------------------------------------------------- 01
INSTALLATION ----------------------------------------------- 01
THREE PHASE MOTOR -------------------------------------- 02
WIRING DIAGRAM ------------------------------------------- 02
PRIMING ------------------------------------------------------ 03
MAINTENANCE ---------------------------------------------- 04
SERVICING --------------------------------------------------- 04
GENERAL SAFETY RULES --------------------------------- 05
ASSEMBLY TASKS
MAINTENANCE TASKS
LOCATION
The pump must be located as close as practical to the pool. The pump must also be
in a position that enables easy access for periodic servicing. Care must also be
taken to position the pump in an area that is free from flooding in a well ventilated
and dry area.
INSTALLATION
Waterco Limited use the latest technology when designing and manufacturing our
pumps, a few simple precautions during installation will ensure years of trouble free
operation.
1. The pump suction line should be not smaller than 1 1/2" (40mm imperial).
2. The suction line is to have as few bends or elbows as possible. There must not be
an air trap on the suction line.
3. Use only the pump barrel unions supplied with the pump.
4. Bolt the pump to the required position (prevent movement).
5. The pump electrical cable must be wired for the proper voltage and rotation in
accordance with the wiring instructions.
6. All wiring (electrical) work must be carried out by licensed electricians and must be
installed in accordance to the local codes.
7. The motor must be grounded.
8. The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.
9. The pump motor cooling fan must have a minimum clearance of 150mm.