7.5" Air Motor with 6:1 Lower Pump Ratio
175 cc/cycle
10
2000
(14, 140)
A
1500
(10, 100)
B
1000
(7, 70)
C
500
(3, 30)
0
0
0.46
(1.75)
Fluid Flow gpm (lpm) tested in No. 10 weight oil
*
See Note in Technical Data, page 52.
333309K
Cycles per Minute
20*
30
0.92
1.39
(3.5)
(5.25)
40
60
(1.7)
50
A
(1.4)
40
B
(1.1)
30
(0.9)
C
20
(0.6)
10
(0.3)
A
= 100 psi (0.7 MPa, 7.0 bar)
1.85
B
= 70 psi (0.48 MPa, 4.8 bar)
(7.0)
C
= 40 psi (0.28 MPa, 2.8 bar)
Performance Charts
KEY
=
fluid flow
=
air consumption
37