Graco M2K Instructions - Parts Manual page 36

Table of Contents

Advertisement

Performance Charts
7.5" Air Motor with 2:1 and 5:1 Lower Pump Ratio
150 cc/cycle
3000
(21, 210)
2500
A
(17, 170)
2000
(14, 140)
B
1500
(10, 100)
C
1000
(7, 70)
500
(3, 30)
0
0
Fluid Flow gpm (lpm) tested in No. 10 weight oil
7.5" Air Motor with 4:1 Lower Pump Ratio
125 cc/cycle
3000
(21, 210)
A
2500
(17, 170)
2000
B
(14, 140)
1500
(10, 100)
C
1000
(7, 70)
500
(3, 30)
0
0
(0.9)
Fluid Flow gpm (lpm) tested in No. 10 weight oil
*
See Note in Technical Data, page 52.
36
Cycles per Minute
10
20*
0.4
0.8
(1.5)
(3.0)
Cycles per Minute
10
15
20*
22
0.25
0.5
0.75
(1.9)
(2.8)
30
40
60
(1.7)
A
50
(1.4)
B
40
(1.1)
30
C
(0.9)
20
(0.6)
10
(0.3)
1.2
1.6
(4.5)
(6.0)
30
38
60
(1.7)
50
A
(1.4)
B
40
(1.1)
30
C
(0.9)
20
(0.6)
10
(0.3)
1.0
1.25
(3.8)
(4.7)
KEY
A
= 100 psi (0.7 MPa, 7.0 bar)
B
= 70 psi (0.48 MPa, 4.8 bar)
C
= 40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
KEY
A
= 100 psi (0.7 MPa, 7.0 bar)
B
= 70 psi (0.48 MPa, 4.8 bar)
C
= 40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
333309K