4.5" Air Motor with 1:1 Lower Pump Ratio (for Polyester Model 24W609)
50 cc/cycle
3000
(20.7, 207)
2500
A
(17.2, 172)
2000
B
(13.8, 138)
1500
(10.3, 103)
1000
C
500
0
Fluid Flow gpm (lpm) tested in No. 10 weight oil
7.5" Air Motor with 1:1 and 3:1 Lower Pump Ratio
100 cc/cycle
4000
(28, 280)
3500
A
(24, 240)
3000
(21, 210)
2500
B
(17, 170)
2000
(14, 140)
1500
C
(10, 100)
1000
(7, 70)
500
(3, 30)
0
0
(0.8)
0
Fluid Flow gpm (lpm) tested in No. 10 weight oil
*
See Note in Technical Data, page 52.
333309K
Cycles per Minute
8
15
20*
23
30
0.4
0.2
(1.5)
(0.8)
Cycles per Minute
8
15
20*
23
0.2
0.4
0.6
(1.5)
(2.3)
38
45
53
61
A
B
C
0.8
0.6
(3.0)
(2.3)
30
38
60
(1.7)
50
A
(1.4)
B
40
(1.1)
30
(0.9)
C
20
(0.6)
10
(0.3)
0.8
1.0
(3.0)
(3.8)
Performance Charts
25
(0.71)
20
(0.57)
15
(0.42)
10
(0.28)
5
(0.14)
KEY
A
= 100 psi (0.7 MPa, 7.0 bar)
B
= 70 psi (0.48 MPa, 4.8 bar)
C
= 40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
KEY
A
= 95 psi (0.65 MPa, 6.5 bar)
B
= 70 psi (0.48 MPa, 4.8 bar)
C
= 40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
35

Advertisement