POSSIBLE ERROR CODES
Error 1: Ambient Temperature High
The ambient temperature read by the control exceeds the ERROR TEMPERA-
TURE limit (85°C + x) specified in EEPROM, or the temperature sensor input
has failed.
Error 2: Heatsink Temperature High
The heatsink temperature read by the control exceeds the ERROR TEMPERA-
TURE limit (110°C + x) specified in EEPROM, or the temperature sensor input
has failed.
Error 3: Ambient and Heatsink Temperature High
The ambient temperature read by the control exceeds the HIGH TEMPERA-
TURE limit (85°C) and the heatsink temperature read by the control exceeds
the HIGH TEMPERATURE limit (110°C) specified in EEPROM.
Error 4: Ambient Thermistor Open
The reading from the ambient temperature thermistor exceeds the open circuit
limit specified in EEPROM.
Error 5: Heatsink Thermistor Open
The reading from the heatsink temperature thermistor exceeds the open circuit
limit specified in EEPROM.
Error 6: Sensor Short
Two or more circuits for the various safety sensors are shorted together.
Error 7: Element Supervisor Fail
The element supervisor circuit has failed on or off. The supervisory circuit will
be monitored at all times (once per second in both idle and active states).
Error 8: Glass-touch Keypad Fail
Communications with the Glass-Touch interface chip have failed.
Error 9: Off Key Error
An error was detected with the global off key.