Wolf E Series Information Booklet page 35

Electronic control
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Priority
1
Keypad circuit error
Keypad comm error detected by
1
the UIM
Keypad comm error detected by
1
the Keypad
1
Keypad FMEA error
1
Keypad EE CRC error
3
Keypad mains sync error
3
UIM EE checksum error
1
UIM configuration data CRC error
1
UIM fuse error
3
UIM ambient thermistor open error
UIM ambient thermistor shorted
3
error
1
LCD module error
Communications error detected by
2
the UIM
Communications error detected by
2
the RM
2
Overtemp error - door unlocked
2
Overtemp error - door locked
2
RM Ambient overtemp error
2
UIM Ambient overtemp error
3
Self-clean rate-of rise error
E-SERIES Error Code Chart (cont.)
Displayed Phrase
Check keypad & connections
Check com harness, replace
Check com harness, replace UIM
Check door motor assy & wiring,
Check air flow, verify cooling fan
operational, replace relay module
Check air flow, verify cooling fan
operational, replace UIM.
Check ovenfor leaks, insulation
problems. Run diagnostics, look
for open ouptuts or loads
PAGE 35
Service Instruction
Replace UIM Module
Relay Module
Module
replace Relay Module
Replace Relay Module