DIAGNOSTICS/SHOWROOM MENU MODE:
Pressing the Timer key for 3 seconds while both cavities are in Idle mode, or
from Showroom mode.
Press 1 = Diagnostics Mode
Press 1 = Self Test*
Press 2 = Manual Test
Press 3 = Error History
Press 4 = Version Info
Press 5 = Statistics
Press 2 = Showroom Mode
Press 2 = Toggle showroom mode on/off
Self Test*
Entry into Auto Self Test will be allowed by entering Diagnostics/Showroom
Mode and choosing Self Test from the Service Mode Entry menu.
Pressing ENTER from initial Auto Self Test menu will start test. URL
displays "SELF TEST ACTIVE". Lower Information Line (LILA) displays
"Testing... please wait". While test is active, CLEAR key will stop testing
and return to the initial Auto Self Test menu. All other keys are inactive except
OFF and LOCK keys, which are always active during diagnostics.
When testing is completed, the Upper Information Line displays "SELF TEST
RESULTS". The LILA shows the results scrolling if necessary. The CLEAR key
is used to return to the initial Auto Self Test menu.
a.
If no problems are found, LILA will display "Self Test Passed".
b.
If an error is found, Service instruction associated with error will be
shown in the LILA. Some instructions reference a particular cavity -
"Upper" or "Lower" will be shown as needed to indicate cavity in
question.
c.
Load presence errors may be detected and will be shown if there
are no higher priority errors detected. If this is the case, the LILA
will display the standard error phrase associated with these failures.