Wolf E Series Information Booklet page 34

Electronic control
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Priority
2
Outer Bake relay shorted
2
Broil relay shorted
2
Left Convect relay shorted
2
Right Convect relay shorted
2
MDL relay shorted
3
Left Convect Fan triac shorted
3
Right Convect Fan triac shorted
Cooling Fan triac shorted
3
3
Oven Light relay shorted
2
DLB1 shorted
DLB2 shorted
2
3
Aux DLB shorted
3
Inner Bake relay open
3
Outer Bake relay open
3
Broil relay open
3
Left Convect relay open
3
Right Convect relay open
3
MDL relay open
3
Left Convect Fan triac open
3
Right Convect Fan triac open
2
Cooling Fan triac open
3
Oven Light relay open
2
DLB1 relay or TCO open
2
DLB2 relay open
2
Aux DLB open
2
RTD Circuitry error
3
RM EE checksum error
3
HIV SPI com err detected by RM control
3
HIV SPI com err detected by HV-micro
3
HIV micro feedback error
1
RM LOV fuse error
3
RM HIV fuse error
2
HSWD active, should be inactive
2
HSWD inactive, should be active
3
RM Ambient Thermistor open error
E-SERIES Error Code Chart (cont.)
Displayed Phrase
PAGE 34
Service Instruction
Check connections,
replace Relay Module of
the oven indicated

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wwd30Df48Df60

Table of Contents