Priority
2
Outer Bake relay shorted
2
Broil relay shorted
2
Left Convect relay shorted
2
Right Convect relay shorted
2
MDL relay shorted
3
Left Convect Fan triac shorted
3
Right Convect Fan triac shorted
Cooling Fan triac shorted
3
3
Oven Light relay shorted
2
DLB1 shorted
DLB2 shorted
2
3
Aux DLB shorted
3
Inner Bake relay open
3
Outer Bake relay open
3
Broil relay open
3
Left Convect relay open
3
Right Convect relay open
3
MDL relay open
3
Left Convect Fan triac open
3
Right Convect Fan triac open
2
Cooling Fan triac open
3
Oven Light relay open
2
DLB1 relay or TCO open
2
DLB2 relay open
2
Aux DLB open
2
RTD Circuitry error
3
RM EE checksum error
3
HIV SPI com err detected by RM control
3
HIV SPI com err detected by HV-micro
3
HIV micro feedback error
1
RM LOV fuse error
3
RM HIV fuse error
2
HSWD active, should be inactive
2
HSWD inactive, should be active
3
RM Ambient Thermistor open error
E-SERIES Error Code Chart (cont.)
Displayed Phrase
PAGE 34
Service Instruction
Check connections,
replace Relay Module of
the oven indicated