Enter into the Manual Test by entering Diagnostics/Showroom Mode (Press and
hold TIMER 3 Seconds) and choosing the Manual Test from the Service Mode
Entry menu (Key Press 2).
NOTE: If a communication failure with the Relay Module exists, Manual Test
entry will be inhibited and an appropriate message displayed in the LILA.
NOTE: Double Oven will default to upper cavity upon entry, press Upper/Lower
key to select cavity being tested.
Component Testing Chart:
Key Press
Relay Active
Key 6
Cooling Fan
Key 7
Motor Door Lock MDS sw open position
Motor Door Lock MDS in transition
Motor Door Lock MDS sw closed position Up arrow illuminated
Key 8
Left Conv Fan
Key 9
Right Conv Fan Right Conv Fan
Up/Lwr
Not applicable
Oven Light
Oven Light
Timed Cook Beeper
Lock
None
Element Testing Chart:
Key Press
Relay(s) Activated
Bake
Inner Bake Element Inner Bake Element On Bake to toggle
Broil
Broil Element
Conv Bake Outer Bake Element Outer Bake Element
Conv Broil
Rt Conv Element
Conv
Lft Conv Element
E-SERIES Manual Test Mode
Action
Cooling Fan
Left Conv Fan
Switch cavity
Light turns on
Beeper
Rtrn to initial Svc Menu
Display Response (Upr and Lwr Info Lines)
Broil Element
Right Conv. Element
Left Conv. Element
PAGE 30
Display Response
Cool Fan Test On
MDS is open
Up arrow illuminated
Lft Conv Fan Test On
Rt Conv Fan Test On
Lights Test On
Beeper Test On
Not applicable
Broil to toggle
Conv. Bake to toggle
Conv. Broil to toggle
Conv. to toggle