How To Connect; Connection Precautions; Cat-5E/6 Cable; Precautions Regarding Low-Voltage Line - Aiphone IXG Series Installation Manual

Guard station, video entrance station, back box for entrance station, lift control adaptor, gateway adaptor.
Table of Contents

Advertisement

How to Connect

■ Connection Precautions

● Cat-5e/6 cable
• For connection between devices, use a straight-through cable.
• If necessary, when bending the cable, please observe the manufacturer's recommendations. Failure to do so could cause a
communication failure.
• Do not strip away the cable insulation any more than is necessary.
• Perform termination in accordance with TIA/EIA-568A or 568B.
• Before connecting the cable, be sure to verify conduction using a LAN checker or similar tool.
• A RJ45 covered connector cannot be connected to the LAN ports of the stations. Use cables without covers on the connectors.
• Be careful not to pull on the cable or subject it to excessive stress.
● Precautions regarding low-voltage line
• Use PE (polyethylene)-insulated PVC jacketed cable. Parallel or jacketed conductors, mid-capacitance, non-
shielded cable is recommended.
• Never use twisted-pair cable or coaxial cable
• 2Pr quad V twisted pair cables cannot be used.
Parallel cable
Coaxial cable
● Connection and disconnection of low-voltage lines
• Insert the line into the quick connection terminal.
• If the line does not go in easily, push the low-voltage line into the terminal while pressing down the detachment
button.
• When removing a low-voltage line, pull on the line while pressing down the detachment button.
• When connecting low-voltage lines, perform the connection using either the crimp sleeve method or soldering,
then insulate the connection with electrical tape.
●Crimp sleeve method
1. Line up the solid wire and
stranded wire and crimp
them together.
Crimp terminal
Solid
Stranded
wire
wire
The shape varies depending on a model.
●Soldering method
2. Overlap the tape by
1. Twist the stranded
at least a half width and
wire around the solid
wrap the connection at
wire at least 3 times.
least twice.
Electrical tape
Solid wire
8mm (5/16")
Detachment
button
Recommended
diameter of wire
ø0.8
2. After bending down the
point, perform soldering,
with care that no wires
protrude from the soldering.
Stranded
wire
- 20 -
3. Overlap the tape by
at least a half width and
wrap the connection at
least twice.
Soldering
Electrical tape

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ixg-mkIxg-dm7Ixg-dm7-hidIxg-dm7-boxIxgw-lcIxgw-gw