Symptom
The unit is not operating.
The unit works with
reduced capacity.
Water Leakage
Excessive Noise
E0
E1
Error
Codes
E2
Ft
TROUBLESHOOTING
Inspection
Check the power connection in
securely.
Check if the water level indicator
lights up?
Check the room temperature.
Check the air filter for dirt.
Check if the air duct is blocked.
Check if the room door or window is
open.
Check if the desired operating mode
is selected and the temperature is
properly set.
The exhaust hose is detached.
Overflow while moving the unit.
Check if the drain hose is kinked or
bends.
Check if the unit is securely
positioned.
Check if any loose, vibrating parts.
Noise sounds like water flowing.
Communication faults between main
PCB and display PCB.
Ambient temperature sensor failure
Coil temperature sensor failures.
Condensate water high level alarm.
Solution
Insert the power cord securely into the wall
Outlet.
Empty the drain pan by remove the rubber
plug.
The range of operating temperature is 5-
35℃.
Clean the air filter as necessary.
To clear the obstacle.
Keep the door and windows closed.
Set the mode and temperature at proper set-
point according the manual.
Make sure the exhaust hose is securely
attached.
Empty the water tank before transport.
Straighten the hose to avoid a trap existing.
Place the unit on horizontal and firm ground.
Secure and tight the parts.
Noise comes from flowing refrigerant. This is
normal.
Check the wire harness of the display PCB for
damage.
Check connection or replace it. To clean or
replace the temperature sensor.
Check connection or replace it. To clean or
replace the temperature sensor.
Empty the drain pan by removal the rubber
plug.