EH1640
4.4 kW (15000 BTU/hour)
Portable Air Conditioner
Climatiseur Local
1
2834
Ver. 2 - 04/14

Advertisement

Table of Contents
loading

Summary of Contents for Prem-I-Air EH1640

  • Page 1 EH1640 4.4 kW (15000 BTU/hour) Portable Air Conditioner Climatiseur Local 2834 Ver. 2 - 04/14...
  • Page 2: Before Use

    3 hours for the refrigerant gas to stabilise before use. INSTALLATION Stand the EH1640 on a firm, flat, level surface. Connect the exhaust hose as follows: expand a small section of the end, and screw into the indoor adaptor;...
  • Page 3 The hose can be expanded up to 1.5 m long, but the shorter it is the more efficiently the EH1640 will operate. Do not extend the hose, or replace with another type of hose. Fit 2 x AAA batteries in to the remote control, observing the correct polarity.
  • Page 4 Replace the bung and cap then reconnect the unit to the mains supply. REMOTE CONTROL STORAGE COMPARTMENT The EH1640 is supplied with a remote control storage compartment on the side of the unit. See figure below. 2834 Ver. 2 - 04/14...
  • Page 5: General Safety Requirements

    GENERAL SAFETY REQUIREMENTS Domestic wiring must be tested periodically by a qualified electrician at least once every 10 years or at every change of occupancy. For office and retail premises, and buildings such as village halls, the wiring must be inspected at least once every 5 years. It is recommended that all building be fitted with smoke alarms (it is mandatory for new buildings).
  • Page 6: Operation

    OPERATION Leave the appliance in an upright position for 3 hours before first use. Plug the mains lead into a 13 Amp mains socket (unless permanently installed). If connecting via an extension lead, make sure that the lead is rated at 13 Amps or more, and that it is fully unwound.
  • Page 7 /Dry mode: removes humidity (dehumidify), but does not affect room • temperature. The fan operates at its lowest speed shown as . For best results, do not use the exhaust tube, but fit a permanent drainage pipe to the drain outlet as shown on page 4. /HEAT mode: heats if the room temperature is below the selected •...
  • Page 8 /SWING (Press buttons at the same time on panel): When selected icon will appear on the LCD screen and the horizontal louvre will slowly raise and lower to distribute the air evenly. Press again to cancel. /Auto Clean: This option only works in Cooling, Heating and Energy saving modes.
  • Page 9: Maintenance

    MAINTENANCE The unit should be cleaned regularly to maintain the best possible operating efficiency and performance. Before any maintenance should be performed turn off the unit and once the fans and compressors have stopped unplug the unit from the mains supply and leave for 3 minutes.
  • Page 10: Operating Costs

    (kilowatt-hour). The amount you are being charged will be shown on your electricity bill. At this cost, the EH1640 will cost £0.19 per hour to run in heating, cooling or dehumidifying modes, and £0.05 per hour to run in the fan-only mode.
  • Page 11: Troubleshooting

    TROUBLESHOOTING If you have any trouble operating this unit please see the table below for simple instructions on how to solve many common problems. Never attempt to open or service the unit and refer all servicing to qualified personnel. Trouble Cause Remedy Connect the unit to a live socket...
  • Page 12: Technical Specification

    TECHNICAL SPECIFICATION Unit BTU/h 15000 Cooling capacity 4400 BTU/h 16000 Heating capacity 4700 Power Supply 230~ Rated Input (Cooling) 1685 Rated Current (Cooling) 7.80 Rated Input (Heating) 1730 Rated Current (Heating) EER for Cooling (R410a) 2.6 (A) COP for Cooling (R410a) 2.7 (A+) Moisture Removal Air Circulation...