Reassembly Procedures - Aqua Lung GLACIA Service & Repair Manual

Second stage regulator
Table of Contents

Advertisement

Glacia Second Stage Service & Repair Manual

REASSEMBLY PROCEDURES

NOTE: Before starting reassembly, it is important to inspect all parts, both new and those that are
being reused, to ensure that every part and component is perfectly clean and free of any dust,
corrosion, or blemishes. Check all o-rings to ensure they are clean and supple before dressing with
either Christo-Lube
WARNING: Use only genuine Aqua Lung parts, subassemblies, and components whenever assem-
bling any Aqua Lung product. DO NOT attempt to substitute an Aqua Lung part with another
manufacturer's, regardless of any similarity in shape, size, or appearance. Doing so may render the
product unsafe, and could result in serious injury or death.
1.
Install the o-ring (28) onto the vane adjustment switch (27).
2.
Mate the stem of the vane switch into its respective hole in the box bottom (29), above the outlet boss,
and align the mating pin above the positioning guide (see Fig. 9). When the switch is correctly aligned,
press it down and into place so that it is properly seated inside the box bottom.
3.
Press the circlip (26) into the recessed ledge in the forks of the Circlip/ Retaining Ring Tool
(P/N 107846), with its flat side facing down and the open end facing out of the tool (see Fig. 10). The
spring tension of the tool will hold the circlip in place while it is being positioned inside the box
bottom.
®
or Dow 111 silicone grease.
Fig. 9 – V.A.S. Alignment
Flat side faces down
Fig. 10 – Loading Circlip Tool
© 2000 Aqua Lung America, Inc.