15. With the front of the second-stage body facing you, place the valve assembly, rounded side facing
upward, into the second-stage and insert it into the hole on the left. The valve body is keyed so it can
only be inserted one way (see Fig. 18).
16. Hold the lever assembly with the lever facing you and the sheath pointing to the left. Insert the lever
assembly into the hole on the right (see Fig. 19).
17. Place a new o-ring (19) onto the insert (18). While keeping the lever assembly pressed against the
sidewall, screw the insert into the lever retainer until fingertight. Attach a 19mm (³⁄₄") crows-foot
adapter to a torque wrench and tighten the insert to 85±3 inch-pounds (see Fig. 20).
Fig. 18 – Installing Valve Body
Fig. 19 – Installing Lever Assembly
Fig. 20 – Installing Retainer