Aqua Lung GLACIA Service & Repair Manual page 21

Second stage regulator
Table of Contents

Advertisement

Glacia Second Stage Service & Repair Manual
PART NUMBER
090015
102035
090027
109511
109508
109509
TEST
Leak test
Intermediate pressure
Intermediate pressure creep Inlet 2,500-3,000 (±100) psi
Opening effort
Flow effort
Purge flow
Table 4
Torque Specifications
DESCRIPTION / KEY NUMBER
LP Hose Female Fitting / 35
Inlet Fitting / 31
Insert / 18
Ribbed Plug / 16
Table 5
Test Bench Specifications
CONDITION
Inlet 2,500-3,000 (±100) psi
Inlet 2,500-3,000 (±100) psi
Inlet 2,500-3,000 (±100) psi,
intermediate pressure 130-135 psi
Intermediate pressure 130-135 psi
at 15 SCFM
Intermediate pressure 130-135 psi
TORQUE
40 (±2) inch-lbs
85 (±3) inch-lbs
85 (±3) inch-lbs
20 (±2)inch-lbs
ACCEPTABLE RANGE
None
130-135 psi
5 psi max between 5 to 15 seconds
after cycling regulator (purge)
+1.0 to +1.6 inch H
0 (primary)
2
+6 inches H
0 (maximum)
2
5.0 SCFM flow rate (minimum)
© 2000 Aqua Lung America, Inc.