First Stage Reassembly Procedures - Aqua Lung APEKS TX 50 Technical Manual

Table of Contents

Advertisement

8
3
Remove the conical filter (36) and o-ring (10) from the yoke
clamp connector (32). Use a 6mm hex key to remove the filter
guard (31) from the clamp connector. Discard filter, guard and o-ring.
DIN Disassembly
1
Secure the vise mounting tool and first stage into a bench
vise. Use a 6mm hex key to loosen the handwheel connector
(34). Lift off the handwheel connector, handwheel (35) and
distance piece (6).
2
Push the conical filter
(36) and o-ring (10) out
of the handwheel connector
(34) using the end of the seat
installation/extraction tool (PN
109437) and discard.
3
Remove the face o-ring (29) from the handwheel connector
(34) and discard.
This Concludes the Disassembly of the
DST First Stage.
Before starting reassembly, perform parts
cleaning and lubrication in accordance with
Procedure A: Cleaning and Lubricating on
page (27).
REASSEMBLY PROCEDURES
DST First Stage Assembly
1
Install the valve lifter (4) into the body (5). Seat the diaphragm
(3) evenly into the body on top of the valve lifter.
2
Place the spring carrier (2) on top of the diaphragm (3),
followed by the spring (1).
3
Install the spring adjuster (22) into the diaphragm clamp
(21) far enough for a couple of threads to catch. Install the
vise mounting tool into the HP port and secure in a bench vise.
Thread the diaphragm clamp to the body (5) and tighten down
using the Apeks spanner wrench (AT30) until you get metal to
metal contact.
TX50 Technical Manual

Advertisement

Table of Contents
loading

Table of Contents