18. Using your fingers, thread the sheath onto the connecting nut until fingertight. While holding the
sheath with a 8mm wrench, tighten the connecting nut with another 8mm wrench (see Fig. 21).
19. While keeping the valve body pressed against the sidewall, thread the inlet fitting (31) into the valve
body (see Fig. 22). Attach a 19mm (³⁄₄") crows-foot adapter to a torque wrench and tighten the inlet
fitting to 85±3 inch-pounds.
20. Install two new o-rings (34 & 36) onto the IP hose.
© 2000 Aqua Lung America, Inc.
Fig. 21 – Tightening Connecting Nut to
Sheath
Press against valve body
Fig. 22 – Install Inlet Fitting
Glacia Second Stage Service & Repair Manual