FINAL ASSEMBLY & TESTING
1.
Install a new o-ring (17) onto the ribbed plug (16). Thread the plug into the insert until fingertight. Attach
a 4mm hex key to a torque wrench and tighten the plug to 20 inch-pounds (see Fig. 25.)
2.
Insert the sealing ring (4) into the diaphragm (5) as shown in Fig. 26a. Insert the diaphragm assembly
into the second-stage as shown in 26b. Make sure the diaphragm is seat against the box bottom.
a.
3.
With the purge button decal properly aligned, slip the left collar of the purge cover over the inlet fitting
(see Fig. 27a). Stretch the right collar over the adjustment port, work the top and bottom of the purge
cover onto the second-stage, making sure the purge cover is properly seated around the perimeter (see
Fig. 27b).
a.
© 2000 Aqua Lung America, Inc.
Fig. 25 – Tourque Plug to xx Inch-
Pounds
b.
Fig. 26 – Install Diaphragm Assembly
b.
Fig. 27 – Install Front Cover
Glacia Second Stage Service & Repair Manual
Make sure cover is seated
properly at the top and bottom