6
16. Separate the spring (9) from the poppet. Using the brass o-ring tool or a safety pin, pierce the center of
low-pressure seat (7) and remove it from the poppet.
17. With the front of the second-stage housing facing you and the mouthpiece opening flat against the
work surface, use a small screwdriver to rotate the vane c-clip so the open end is facing you. While
holding the box bottom secure, place the tines of the Micra Pre-adjustment Tool (P/N 100168) squarely
against the ends of the circlip (26) as shown in Fig. 8. Gently press the circlip straight off the vane
adjustment switch (27), and set it aside.
18. Pull the vane adjustment switch straight up and out of the outlet boss of the box bottom. Remove and
discard the o-ring (28), and set the switch aside.
This concludes the disassembly of the Glacia second stage. Refer directly to Procedure A and
Table A, titled "Cleaning & Lubrication" , before proceeding to the Reassembly Procedures.
© 2000 Aqua Lung America, Inc.
Fig. 8 – V.A.S. Circlip Removal
Glacia Second Stage Service & Repair Manual