Advertisement

 6 mm tube fitting on weather cap, for detector validation including the proof
test (see Section 6).
 Window and mirror, for cleaning (described in [RD 1],
 Battery replacement (described in [RD 1],
1.7

Device configurations

The following table lists all available configurations of the GS01 gas detector,
which meet the specific safety requirements of IEC 61508 and IEC 61511:

Table 1-1: GS01 device configurations

Product number Firmware
GS-01 Config-1
GS-01 Config-2
GS-01 Config-129
GS-01 Config-130
GS-01 Config-65
GS-01 Config-66
GS-01 Config-193
GS-01 Config-194
The above GS01 configurations are selected during commissioning of the device.
The configuration is implemented as iParameter i.e. individual or technology
specific device parameters in PROFIsafe [RD 3]. The controller shall be set up
with the corresponding iParameter for each detector address for verification of the
configuration. Communication is not possible when the IPAR_CRC value is not
assigned.
6
Calibration /
version
data type
≥ 3.0
Methane IEC /
Float
≥ 3.0
Propane IEC /
Float
≥ 3.3
Methane NIOSH
/ Float
≥ 3.3
Propane NIOSH
/ Float
≥ 3.4
Methane IEC /
INT16
≥ 3.4
Propane IEC /
INT16
≥ 3.4
Methane NIOSH
/ INT16
≥ 3.4
Propane NIOSH
/ INT16
GasSecure GS01
Safety Manual
SIL
IPAR_0
IPAR_CRC
level
SIL 2
1
0xF4ACFB13
SIL 2
2
0x1DF50D35
SIL 2
129
0x5B5C5A1F
SIL 2
130
0xB205AC39
SIL 2
65
0xA354AB95
SIL 2
66
0x4A0D5DB3
SIL 2
193
0x0CA40A99
SIL 2
194
0xE5FDFCBF