Victron energy Orion Manual page 5

Dc-dc smart charger non-isolated
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
completely recharged. For lithium batteries absorption time is
fixed, typically 2 hours, the fixed or adaptive mode can be chosen
on the battery settings.
Float
During this stage, float voltage is applied to the battery to
maintain it in a fully charged state. When the battery voltage
drops below re-bulk voltage, due to a high load, during at least 1
minute a new charge cycle will be triggered.
Flexible charge algorithm
Programmable charge algorithm, and eight preprogrammed
battery settings.
Configurable with VictronConnect.
Adaptive absorption time
Automatically calculates the proper absorption time.
Configurable with Victron Connect.
Configuring and monitoring
Bluetooth Smart built-in: the wireless solution to set-up, monitor
and update the controller using Apple and Android smartphones,
tablets or other devices.
Several parameters can be customized with the VictronConnect
app.
The VictronConnect app can be downloaded from:
http://www.victronenergy.nl/support-and-downloads/software/
Use the manual – VictronConnect - to get the most out of the
VictronConnect App when it's connected to an Orion Smart:
https://www.victronenergy.com/live/victronconnect:start
Input voltage lock-out
Shutdown if the input voltage drops below the lock-out value and
continuous when the input voltage increases above the restart
value.
Configurable with Victron Connect.
3