User Manual
G
d
eneral
escription
Display:
LCD screen with background, max reading of
"1999"
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
Sampling updates:
Measurement range selection: automatic or manual
Measurement category:
Power Source:
Size:
Weight:
Overload Protection and Overvoltage Protection
Auto Turn On/Off function
Data Hold Function
s
i
afety
nforMation
To avoid possible electric shock or personal injury, fol-
low these guidelines:
Protect yourself against electric shock.
Avoid any misuse or improper usage to protect
the device from any damage.
Before measuring current, check the Meter's ac-
cessories (fuses, probes), ensure the good wor-
king condition, to avoid any damage. Do not use
the device with damaged test leads.
Do not use the Meter around devices with high
electricity and frequency which can generate
interference, due to avoid misuse, false measu-
rement, damage or immeasurable values on the
screen.
Use the device only according to the guidlines
and for appropriate measurements. If you misuse
the Meter, it cannot work properly in the future.
Do not operate the Meter around explosive gas,
vapor, or dust.
Check the device before every usage, verify the
Meter's operation in the selected position and en-
sure the connection of the test leads.
If you do not know the range what you want to
measure, set up the switch to the highest measu-
ring value and go backwards until it achieves the
appropriate range.
To avoid any damage, do not use the device for
measuring more than the rated input voltage.
Use caution when working with voltages above
60V dc, or 30V ac. These voltages pose a shock
hazard.
When using the probes, keep the fingers behind
the finger guards.
Before rotating the range switch to select functi-
ons, disconnect test leads from the circuit under
test.
To avoid possible damage to the Meter or to the
equipment under test, disconnect circuit power
and discharge all high-voltage capacitors before
testing diodes, continuity or resistance.
0°C - 40°C
(32°F - 104°F)
<80% RH
-10°C - 60°C
(14°F - 122°F)
<70% RH
3/mp
Cat III 500V
1x 6F22 9V elem
144 x 70 x 32mm
~200g (with battery)
Before measuring current turn OFF power to the
circuit before connecting the Meter to the circuit.
Replace the batteries as soon as the battery indi-
cator appears on the screen.
Disconnect test leads before opening the case or
the battery door.
Do not use the Meter if it operates abnormally.
If the product is not in use, remove the battery
and store the Meter in a cool, dry place, and do
not store in highly humid environment.
To avoid fire, or any damage, replace fuses only
with the specified ratings: F 200mA/250V,
10A/250V.
Do not use the device if the back battery cover is
open or does not fit closed and fixed properly.
1
2
3
4
5
1. LCD display
2. POWER – turn on/off button
3. HOLD – Date Hold button
4. Function switch
5. „A" jack – Input for 10A current measurements
6. Light sensor (for the backlight)
7. NCV LED –
Voltage detector function display LED
8. Backlight turn on/off button
9. „COM" – common input terminal
10. mA/V/
/Ω/ terminal, (hereafter „V" terminal)
f
Unction
HOLD button
Data hold function.To hold the present reading, press
the data hold button for a while. Press the button again
to resume normal operation.
Power button
Press the power button once to turn the device on or
off.
F
6
7
8
9
10