Maktek 20 MK Installation, Operation And Maintenance Instructions page 5

Table of Contents

Advertisement

1- Ignition Transformer
2- Photocell
3- Condenser
4- Burner Engine
5- Fuel Pump
6- Solenoid
7- Brain
* The device is secured by pressure prosestat. Device will not enter the circuit unless sufficiant
close- circuit pressure is provided.
B. GENERAL USAGE RULES
1- Switch off your device when you are filling the depot with diesel and wait for 1 hour without
working.
2- Before restarting the unit, drain the sediment and water that accumulate on the bottom of the
boiler by opening draining valve.
3- Clean the diesel filters at the outlet of the tank every 30 days. After the filter is cleaned, drain
the air of the circuit.
4- Clean the electrodes and the turbulator of the burner every 6 days with a dry cloth.
5- Clean it with a photocell every 60 days.
6- At the beginning of each winter season, clean the soot has accumulated in the boiler.
7- Clean the burner nozzle every 4 months.
Note: It is recommended that the maintenance procedures specified in items 4, 5, 6 and 7 are
carried out by your authorized service.