Chattanooga Intelect Mobile 2 Quick Start Manual
Hide thumbs Also See for Intelect Mobile 2:

Advertisement

Quick Links

Guide de démarrage rapide • Kurzanleitung • Guía de inicio rápido
Snelle start gids • Guida rapida d'avvio • Hızlı başlama rehberi
CO M B O, S T I M, U LT R A S O U N D

Advertisement

Table of Contents
loading

Summary of Contents for Chattanooga Intelect Mobile 2

  • Page 1 Guide de démarrage rapide • Kurzanleitung • Guía de inicio rápido Snelle start gids • Guida rapida d’avvio • Hızlı başlama rehberi CO M B O, S T I M, U LT R A S O U N D...
  • Page 2: Table Of Contents

    I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E C O N T E N T S Foreword ���������������������������������������������������� 3 Optional Vacuum Module ���������������������10 Intended User Profile ������������������������������...
  • Page 3: Foreword

    This guide is intended for users of Intelect Mobile ® The intelect Mobile 2 device will be used to deliver 2 . It contains general information on operation, a variety of modalities to the patient, ultrasound, precautionary practices, and maintenance.
  • Page 4 I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E CAUTION • This unit should be operated at +5°C to +40°C and 15% to 90% Relative Humidity. The unit should be transported and stored at -20°C to +60°C and 10% to 90% Relative Humidity.
  • Page 5 STIMULATOR electrodes and possible damage to the STIMULATOR. • Portable RF communications equipment should be used no closer than 30 cm (12 inches) to any part of the Intelect Mobile 2, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
  • Page 6 I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E WARNING • The Intelect® Mobile 2 may be susceptible to Electro-Static Discharge (ESD) at greater than ±6 kV when first grasping the Ultrasound applicator.
  • Page 7 DANGER • DO NOT connect the unit to an electrical supply without first verifying that the power supply is the correct voltage. Incorrect voltage may cause unit damage, malfunction, electrical shock, fire, or personal injury. Your unit was constructed to operate only on the electrical voltage specified on the Voltage Rating and Serial Number Plate.
  • Page 8: Contraindications

    I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E C O N T R A I N D I C A T I O N S ELECTROTHERAPY The Intelect Mobile 2 should NOT be used under the...
  • Page 9: Ultrasound

    C O N T R A I N D I C A T I O N S ULTRASOUND • Do not use for symptomatic local pain relief unless etiology is established or unless a pain syndrome has been diagnosed. • Do not use when cancerous lesions are present in the treatment area.
  • Page 10: Product Description

    HEAD TO CART FIXATION Throughout these instructions the terms “left” and“right” referring to the machine sides are from the See Intelect Mobile 2 Instructions for Use perspective of a user standing in front of the unit. The components of the Intelect Mobile 2 are shown ®...
  • Page 11: Device Description

    DEVICE DESCRIPTION Handle Colour Touch Screen ON/OFF button Play / pause button Ultrasound applicator support Adjustment dial Battery cover Vacuum cover ON / OFF switch only USB port for active on mains power software upgrade Mains power connector Ultrasound applicator Lead wire connectors for connectors electro stimulation...
  • Page 12: Connecting Cables And Inserting Plugs

    IF UNIT SUPPLIED WITH OPTIONAL PLUGS BATTERY After unpacking Intelect Mobile 2 to fit the battery When inserting the plugs, be sure to align the flat side follow the following steps of the plug with the flat side of the slot and push in 1.
  • Page 13: Ifu Download

    Switch device on with switch on the back of the unit, 3. Complete the registration form to be informed do not position the Intelect Mobile 2 in such a way about new product software version availability and that makes it difficult to disconnect from the mains IFU updates.
  • Page 14: Device Connected To The Mains

    I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E DEVICE CONNECTED TO THE MAINS TO STOP TREATMENT AND STOP THE DEVICE 1.
  • Page 15: Home Screen Icon Descriptions

    HOME SCREEN ICON DESCRIPTIONS DESCRIPTION OF DEVICE MARKINGS Refer to Instructional Manual Stim Booklet Ultrasound Warning, Caution, or Danger Electrical Type BF Equipment Combo Shortcut Ultrasound SPS (Suggested Parameter Setup) Stim Custom Protocols Combo Treatment Data Play Pause Clinical Resources Home ON/OFF Settings...
  • Page 16 I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E This end up Keep dry Temperature Range Relative Humidity Range Atmospheric Pressure Range Testing agency CE Mark of Conformity with notified body number...
  • Page 17: Appendix

    CC = constant current, effect of load Width Depth Height impedance on voltage battery) CV = constant voltage, effect of load Intelect Mobile 2 Head Unit impedance on current Output specifications are described for each waveform COMBO 34cm 35.5cm 15cm 3.1kg...
  • Page 18 Atmospheric Pressure: 50kPa to 106kPa Pulsed mode Time required for the Intelect Mobile 2 to warm from the minimum storage temperature between uses until (*) An error of + 0.25 W can be measured with 1cm2 the Intelect Mobile 2 is ready for its INTENDED USE US applicator, pulse mode 100Hz at 10% or 20% Duty when the ambient temperature is 20 °C: 5h...
  • Page 19 A P P E N D I X Time required for the Intelect Mobile 2 to cool from the maximum storage temperature between uses until the Intelect Mobile 2 is ready for its INTENDED USE when the ambient temperature is 20 °C: 5h...
  • Page 20 I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E A P P E N D I X WAVEFORMS CC: Constant Current CV: Constant Voltage IFC (Interferential) Traditional (4 Pole) TENS- Asymmetrical Biphasic...
  • Page 21 A P P E N D I X ™ TENS- Symmetrical Biphasic Advice on size and type of electrodes to be used is given in device GUI "treatment Advice on size and type of electrodes to be used is given in device GUI "treatment guidelines"...
  • Page 22 I N T E L E C T ® M O B I L E 2 Q U I C K S TA RT G U I D E A P P E N D I X IFC Premodulated (Traditional 2 Pole) High Voltage Pulsed Current (HVPC) Advice on size and type of electrodes to be used is given in device GUI "treatment Advice on size and type of electrodes to be used is given in device GUI "treatment...
  • Page 24 DJO France SAS Centre Européen de Frêt 3 rue de Bethar 64990 Mouguerre • France T: + 33 (0) 5 59 52 86 90 • F: + 33 (0) 5 59 52 86 91 DJOglobal.com DJO, LLC | 1430 Decision Street | Vista | CA 92081-8553 | U.S.A. www.DJOglobal.com...

Table of Contents