  • Page 2: Table Of Contents

    TABLE OF CONTENTS Intelect® Legend Series Combo FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Ultrasound .
  • Page 3: Foreword

    FOREWORD Intelect® Legend Series Combo This manual has been written for the owners and operators of the Intelect ® Legend Series Combo, models 2C and 4C. It contains general instructions on operation, precautionary practices, maintenance and parts information. In order to maximize use, efficiency and the life of your unit, please read this manual thoroughly and become familiar with the controls as well as the accessories before operating the unit.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS Intelect® Legend Series Combo PRECAUTIONARY INSTRUCTIONS The precautionary instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this equipment. The DANGER definitions of these symbols are as follows: Text with a “DANGER”...
  • Page 5 • internal electrical power source. The Intelect Legend Series Combo is not designed to prevent the • ingress of water or liquids. Ingress of water or liquids could cause DO NOT disassemble, modify, or remodel the unit or accessories.
  • Page 6 SAFETY PRECAUTIONS Intelect® Legend Series Combo • • Powered muscle stimulators should be used only with the leads and DO NOT remove the cover. This may cause unit damage, electrodes recommended for use by the manufacturer. malfunction, electrical shock, fire, or personal injury. There are •...
  • Page 7: Dangers

    SAFETY PRECAUTIONS Intelect® Legend Series Combo • Always keep the sound head in full contact with the patient’ s skin or • Patients with an implanted neurostimulation device submerged under water when setting intensity. must not be treated with or be in close proximity to •...
  • Page 8: Warnings

    SAFETY PRECAUTIONS Intelect® Legend Series Combo INDICATIONS/CONTRAINDICATIONS AND ADVERSE EFFECTS FOR ELECTRICAL STIMULATION Interferential and Premodulated Indications • Symptomatic relief of chronic, intractable pain • Management of pain associated with post-traumatic or postoperative conditions Contraindications • This device should not be used for symptomatic pain relief unless etiology is established or unless a pain syndrome has been diagnosed.
  • Page 9 SAFETY PRECAUTIONS Intelect® Legend Series Combo INDICATIONS/CONTRAINDICATIONS AND ADVERSE EFFECTS FOR ELECTRICAL STIMULATION Precautions • Isolated cases of skin rash may occur at the site of electrode placement following long-term applications. The irritation may be reduced by use of an alternate conductive medium or an alternative electrode placement. •...
  • Page 10 SAFETY PRECAUTIONS Intelect® Legend Series Combo INDICATIONS/CONTRAINDICATIONS AND ADVERSE EFFECTS FOR ELECTRICAL STIMULATION Warnings • The long-term effects of chronic electrical stimulation are unknown. • Safety has not been established for the use of therapeutic electrical stimulation during pregnancy. • Adequate precautions should be taken when treating individuals with suspected or diagnosed heart problems. •...
  • Page 11 SAFETY PRECAUTIONS Intelect® Legend Series Combo INDICATIONS/CONTRAINDICATIONS AND ADVERSE EFFECTS FOR ELECTRICAL STIMULATION • Over the menstruating uterus. • Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or the electrical conductive medium. The irritations can usually be reduced by the use of an alternate conductive medium or alternative electrode placement.
  • Page 12 SAFETY PRECAUTIONS Intelect® Legend Series Combo • Other contraindications are patients suspected of carrying serious infectious disease and or disease where it is advisable, for general medical purposes, to suppress heat or fevers. • This device should not be used over or near bone growth centers until bone growth is complete. • This device should not be used over the thoracic area if the patient is using a cardiac pacemaker. • This device should not be used over a healing fracture. • This device should not be used over or applied to the eye. • This device should not be used over a pregnant uterus. • This device should not be used on ischemic tissues in individuals with vascular disease where the blood supply would be unable to follow the increase in metabolic demand and tissue necrosis might result. • Patients with an implanted neurostimulation device must not be treated with or be in close proximity to any shortwave diathermy, microwave diathermy, therapeutic ultrasound diathermy or laser diathermy anywhere on their body. Energy from diathermy (shortwave, microwave, ultrasound and laser) can be transferred through the implanted neurostimulation system, can cause tissue damage and can result in severe injury or death.
  • Page 13: Overview

    OVERVIEW Intelect® Legend Series Combo Operator Interface – The operator interface consists of a Liquid Crystal Display (LCD) and three Light Emitting Diodes (LEDs). The operator is able to view Channel designation, Treatment time and Output on the LEDs and Parameter options on the LCD.
  • Page 14 Intelect® Legend Series Combo The software control of the Intelect Legend Series Combo has been designed to be extremely user friendly. First press the treatment mode button of your choice, increase intensity and press start. The software also allows great flexibility should you desire to change parameters.
  • Page 15: Nomenclature

    Ultrasound. The advanced electronics of the Intelect Legend Series Combo transmits stored data from the applicator to the unit each time the device is powered on and ultrasound is accessed. This sophisticated Electronic Signature™...
  • Page 16: Specifications

    SPECIFICATIONS Intelect® Legend Series Combo Stimulator Output Parameters Parameter Interferential Premodulated Function Electrodes Electrodes Carrier Frequency 5000 Hz 5000 Hz Beat Frequency 0-200 Hz 0-200 Hz Scan Mode On/Off Scan Time 15 sec Sweep Time 15 sec 15 sec Duty Cycle Ramp Up / Ramp Down Cycle Time 15 sec...
  • Page 17 SPECIFICATIONS Intelect® Legend Series Combo Stimulator Output Parameters Parameter Russian High Volt Function Mode Electrodes Electrodes, Probes Single, Recipr. Single Co-Contraction Carrier Frequency 2500 Hz Pulse Frequency 10 -120 pps Burst Frequency 20-100 BPS Phase Duration Interphase Interval Duty Cycle 10-50% Ramp Up / Ramp Down 5, 1, 2, 5 sec...
  • Page 18: Ultrasound Output Parameters

    SPECIFICATIONS Intelect® Legend Series Combo Ultrasound Output Parameters Channel US (Ultrasound) Frequency 1 MHz ± 5% & 3.3 MHz ± 5% Duty Cycle 100% (continuous mode) 50%, 20%, 10% (pulsed mode) Pulse Duration 5 msec ± 20% (50% duty cycle, pulsed mode) 2 msec ±...
  • Page 19: Setup

    Intelect® Legend Series Combo Optional Accessories Initial Setup Instructions Remove the Intelect Legend Series Combo unit and any addi- The following is a list of optional accessories available for the tional items ordered from the carton and inspect for damage Intelect Legend Series Combo: that may have occurred during shipment.
  • Page 20: Operation

    OPERATION Intelect® Legend Series Combo Pain Management The management of post-traumatic, post-operative or chronic intractable pain associated with many areas of the body can be a difficult task. The ntelect Legend Series Combo provides multiple waveforms and many parameter settings to manage pain. Two waveforms are available for Pain Management therapy: Interferential and Premodulated.
  • Page 21 OPERATION Intelect® Legend Series Combo Ch. Select Amplitude Modulation/Scan Percentage When you highlight Beat Frequency and press the button, 5 options are displayed. They are 1-10 Hz, 80-150 Hz (default), enter 1-150 Hz, Variable and Fixed. The Variable option allows you to select a Low Beat frequency from 1-200 Hz and a High Beat frequency from 1-200 Hz. To make changes in the Variable frequency, highlight and press the button.
  • Page 22 OPERATION Intelect® Legend Series Combo The Fixed Option, allows you to select a fixed frequency from 1-200 Hz. To make changes to the Fixed frequency, highlight fixed press . Use the arrows to adjust frequency. Press to accept. enter down enter Beat Frequency Beat Low...
  • Page 23: Premodulated

    OPERATION Intelect® Legend Series Combo Premodulated Premodulated is an amplitude modulated sine wave. This waveform is similar to the beat frequency created by Interferential current. In some cases, Premodulated therapy provides a good alternative for Interferential treatment especially when treating areas of the body where four electrodes can not be utilized.
  • Page 24: Muscle Contraction

    The Intelect Legend Series Combo provides multiple waveforms to address these clinical problems.
  • Page 25 OPERATION Intelect® Legend Series Combo Sweep is frequency modulation of the High Volt current. When you select and press the button, 4 options are displayed. sweep enter They are Continuous (default at 100 pps), 1-10 Hz, 80-150 Hz and 1-150 Hz. The Continuous option allows you to select a continuous fixed frequency from 1-120 pps.
  • Page 26: Russian

    OPERATION Intelect® Legend Series Combo Russian The Russian current is a 2,500 Hz sinusoidal carrier wave, interrupted to create pulse trains or "bursts. " The number of bursts per second is determined by the burst frequency and the length of the bursts is determined by the duty cycle. Mode provides three methods of treatment including Single channel application, Reciprocal application where stimulation alternates between agonists and antagonists and Co-Contract where the timing of stimulation can be coordinated through two channels to simultaneously...
  • Page 27: Ultrasound

    OPERATION Intelect® Legend Series Combo Ultrasound Ultrasound is a form of mechanical energy that consists of high frequency vibrations delivered to the body by means of an ultrasound beam emitted out of an applicator. These high frequency vibrations pass through the tissues of the body and are gradually absorbed and transformed into heat.
  • Page 28: Combination Therapy

    OPERATION Intelect® Legend Series Combo Combination Therapy In the Combination mode, ultrasound therapy is combined with Interferential, Premodulated or High Volt (default) to generate a therapeutic effect. In this mode of therapy the aluminum face of the ultrasound applicator becomes one half of the electrical circuit. An electrode attached to the Red lead wire marked “2”...
  • Page 29: Miscellaneous

    OPERATION Intelect® Legend Series Combo Miscellaneous To Change Presets • Select and modify desired parameter(s). • Press and hold the button, then press the button. pause enter To Change LCD Screen Contrast: • Press and hold the button. main menu •...
  • Page 30: Maintenance

    To fully maintain compliance with Federal Regulation Title 21 (21 CFR), this unit must be recalibrated annually. It is recommended that all Chattanooga ultrasound products be returned to the factory or an authorized servicing dealer for repairs or recalibration. It is also recommended after the replacement or repair of any major component.
  • Page 31: Warranty

    Intelect® Legend Series Combo DJO, LLC ("Company"), warrants that the Intelect Legend Series Combo ("Product") is free of defects in material and workmanship. This warranty shall remain in effect for two years (24 months) from the date of original consumer purchase. If this Product fails to function during the two year warranty period due to a defect in material or workmanship, at the Company's option, the Company or the selling dealer will repair or replace this Product without charge within a period of thirty days from the date on which the Product is returned to the Company or the dealer.
  • Page 32 Moving Rehabilitation Forward™ ISO 13485 Certified DJO, LLC 1430 Decision St Vista, CA 92081 USA T: 1-800-592-7329 USA T: + 1-317-406-2209 F: + 1-317-406-2014 chattgroup.com © 2010 DJO, LLC 28389_C...
  • Page 33 FUNCIONAMIENTO Intelect® Legend Series Combo Varios Para cambiar la configuración predeterminada • Seleccione y modifique el (los) parámetro(s) deseado(s). • Mantenga pulsado el botón (pausar), y a continuación pulse el botón (intro). pause enter Para cambiar el contraste de la pantalla LCD: •...
  • Page 34 Para cumplir plenamente el Título de Reglamentos Federales 21 (21 CFR), esta unidad debe ser recalibrada anualmente. Se recomienda que todos los pro- ductos de ultrasonido Chattanooga sean devueltos a la fábrica o a un distribuidor de servicio autorizado, para su reparación o recalibración. También se recomienda la recalibración después de la sustitución o reparación de cualquiera de los componentes principales.
  • Page 35 Intelect® Legend Series Combo DJO, LLC (la “Compañía”), garantiza que el Intelect Legend Series Combo (el “Producto”) no tiene defectos en materiales ni en mano de obra. Esta garantía permanecerá vigente durante dos años (24 meses) a partir de la fecha de compra del usuario original. Si el producto deja de funcionar durante el período de garantía de dos años debido a un defecto de material o mano de obra, la Compañía o el concesionario (a opción de la Compañía) reparará...
  • Page 36 DESCRIPCIÓN GENERAL Intelect® Legend Series Combo Interfaz del operador – La interfaz del operador consiste en una pantalla de cristal líquido (LCD) y tres diodos emisores de luz (LED). Mediante los LED y las opciones de parámetros en la pantalla LCD, el operador puede ver la designación del canal, el tiempo de tratamiento y la salida.
  • Page 37 Intelect® Legend Series Combo El software de control del Intelect Legend Series Combo ha sido diseñado de modo que es extremadamente fácil de usar. Primero pulse el botón de modo de tratamiento de su elección, aumente la intensidad y pulse el botón de inicio. El software también permite una gran flexibilidad en caso de que desee cambiar los parámetros.
  • Page 38 Panel derecho del Modelo 2C Panel lateral izquierdo de los modelos Puerto de ultrasonido – El Intelect Legend Series Combo incluye un aplicador de ultrasonido de 5 cm que se conecta al puerto marcado con la palabra “Ultrasound” (ultrasonido). El avanzado sistema electrónico del Intelect Legend Series Combo transmite los datos almacenados desde el aplicador a...
  • Page 39 ESPECIFICACIONES Intelect® Legend Series Combo Parámetros de salida del estimulador Parámetro Interferencial Premodulado Función Electrodos Electrodos Frecuencia portadora 5000 Hz 5000 Hz Frecuencia de pulsación 0-200 Hz 0-200 Hz Modo de escaneo Encendido/Apagado Duración del escaneo 15 seg. Tiempo de barrido 15 seg.
  • Page 40 ESPECIFICACIONES Intelect® Legend Series Combo Parámetros de salida del estimulador Parámetro Russian High Volt (Alto voltaje) Modo de función Electrodos Electrodos, sondas Individual, Recipr., Individual Co-contracción Frecuencia portadora 2500 Hz Frecuencia del pulso 10-120 pps Frecuencia de la ráfaga 20-100 BPS Duración de la fase Intervalo de la interfase Ciclo de funcionamiento...
  • Page 41 ESPECIFICACIONES Intelect® Legend Series Combo Parámetros de la salida de ultrasonido Canal US (Ultrasonido) Frecuencia 1 MHz ± 5% y 3,3 MHz ± 5% Ciclo de funcionamiento 100% (modo continuo) 50%, 20%, 10% (modo pulsado) Duración del pulso 5 mseg ± 20% (ciclo de funcionamiento del 50%, modo pulsado) 2 mseg ±...
  • Page 42 Accesorios opcionales Instrucciones para la configuración inicial Retire de la caja la unidad Intelect Legend Series unidad Combo y cual- La siguiente es una lista de accesorios opcionales disponibles para la quier artículo adicional incluido en el pedido e inspecciónelos por si unidad Intelect Legend Series Combo: se hubieran producido daños durante el envío.
  • Page 43 El control de dolor resistente a tratamientos (en situaciones post-traumáticas, post-operatorias o crónicas) que aparece en muchas áreas del cuerpo puede ser una tarea difícil. El Intelect Legend Series Combo ofrece múltiples formas de onda y muchas configuraciones de parámetros para controlar el dolor.
  • Page 44 FUNCIONAMIENTO Intelect® Legend Series Combo Selección de canal Modulación de amplitud / Porcentaje de escaneo Cuando resalte Beat Frequency (Frecuencia de pulsación) y pulse el botón (intro), aparecen 5 opciones. Son 1-10 Hz, 80-150 Hz (valor prede- enter terminado), 1-150 Hz, Variable y Fij a. La opción Variable le permite seleccionar una frecuencia de pulsación baja, de 1 a 200 Hz, y una frecuencia de pulsación alta, de 1 a 200 Hz.
  • Page 45 FUNCIONAMIENTO Intelect® Legend Series Combo La opción Fixed Option (fija), le permite seleccionar una frecuencia fija en el intervalo de 1 a 200 Hz. Para realizar cambios en la frecuencia fija, resal- te la opción (fija) y pulse el botón (intro).
  • Page 46 FUNCIONAMIENTO Intelect® Legend Series Combo Premodulada La opción “Premodulated” (premodulada) es una onda senoidal de amplitud modulada. Esta forma de onda es similar a la frecuencia de pulsación creada por la corriente interferencial. En algunos casos, la opción de terapia “Premodulated” (premodulada) ofrece una buena alternativa para el tratamiento interferencial, sobre todo en el tratamiento de las áreas del cuerpo donde no se pueden utilizar cuatro electrodos.
  • Page 47 El Intelect Legend Series Combo ofrece múlti- ples formas de onda para resolver estos problemas clínicos.
  • Page 48 El Intelect Legend Series Combo ofrece múlti- ples formas de onda para resolver estos problemas clínicos.
  • Page 49 FUNCIONAMIENTO Intelect® Legend Series Combo Sweep (barrido) es la modulación de la frecuencia de la corriente de alto voltaje. Cuando selecciona la opción y pulsa el botón (intro), se sweep enter muestran 4 opciones. Son “Continuous” (continua) (valor predeterminado a 100 pps), 1-10 Hz, 80-150 Hz y 1-150 Hz. La opción “Continuous” le permite seleccionar una frecuencia continua fija en el intervalo de 1 a 120 pps.
  • Page 50 FUNCIONAMIENTO Intelect® Legend Series Combo Russian La corriente “Russian” (rusa) es una onda portadora sinusoidal de 2500 Hz, interrumpida para crear secuencias de pulsos o “ráfagas”. El número de ráfagas por segundo se determina por la frecuencia de la ráfaga, y la duración de las ráfagas se determina por el ciclo de funcionamiento. Mode (modo) proporciona tres métodos de tratamiento, inclusive la aplicación de un solo canal (Single), la aplicación “Reciprocal”...
  • Page 51 FUNCIONAMIENTO Intelect® Legend Series Combo Ultrasonido El ultrasonido es una forma de energía mecánica que consiste de vibraciones de alta frecuencia aplicadas al cuerpo por medio de un haz de ultrasonidos emitidos a través de un aplicador. Estas vibraciones de alta frecuen- cia pasan a través de los tejidos del cuerpo y poco a poco son absorbidas y transformadas en calor.
  • Page 52 FUNCIONAMIENTO Intelect® Legend Series Combo Terapia de combinación En el modo “Combination” (combinación), la terapia de ultrasonido se combina con la terapia “Interferential” (interferencial), “Premodulated” (premodulada) o “High Volt” (alto voltaje) (predeterminada) a fin de generar un efecto terapéutico. En este modo de terapia la superficie de aluminio del aplicador de ultra- sonido pasa a ser la mitad del circuito eléctrico.
  • Page 53 FUNCIONAMIENTO Intelect® Legend Series Combo Varios Para cambiar la configuración predeterminada • Seleccione y modifique el (los) parámetro(s) deseado(s). • Mantenga pulsado el botón (pausar), y a continuación pulse el botón (intro). pause enter Para cambiar el contraste de la pantalla LCD: •...
  • Page 54 Para cumplir plenamente el Título de Reglamentos Federales 21 (21 CFR), esta unidad debe ser recalibrada anualmente. Se recomienda que todos los pro- ductos de ultrasonido Chattanooga sean devueltos a la fábrica o a un distribuidor de servicio autorizado, para su reparación o recalibración. También se recomienda la recalibración después de la sustitución o reparación de cualquiera de los componentes principales.
  • Page 55 Intelect® Legend Series Combo DJO, LLC (la “Compañía”), garantiza que el Intelect Legend Series Combo (el “Producto”) no tiene defectos en materiales ni en mano de obra. Esta garantía permanecerá vigente durante dos años (24 meses) a partir de la fecha de compra del usuario original. Si el producto deja de funcionar durante el período de garantía de dos años debido a un defecto de material o mano de obra, la Compañía o el concesionario (a opción de la Compañía) reparará...
  • Page 56 FUNCIONAMIENTO Intelect® Legend Series Combo Sweep (barrido) es la modulación de la frecuencia de la corriente de alto voltaje. Cuando selecciona la opción y pulsa el botón (intro), se sweep enter muestran 4 opciones. Son “Continuous” (continua) (valor predeterminado a 100 pps), 1-10 Hz, 80-150 Hz y 1-150 Hz. La opción “Continuous” le permite seleccionar una frecuencia continua fija en el intervalo de 1 a 120 pps.
  • Page 57 FUNCIONAMIENTO Intelect® Legend Series Combo Russian La corriente “Russian” (rusa) es una onda portadora sinusoidal de 2500 Hz, interrumpida para crear secuencias de pulsos o “ráfagas”. El número de ráfagas por segundo se determina por la frecuencia de la ráfaga, y la duración de las ráfagas se determina por el ciclo de funcionamiento. Mode (modo) proporciona tres métodos de tratamiento, inclusive la aplicación de un solo canal (Single), la aplicación “Reciprocal”...
  • Page 58 FUNCIONAMIENTO Intelect® Legend Series Combo Ultrasonido El ultrasonido es una forma de energía mecánica que consiste de vibraciones de alta frecuencia aplicadas al cuerpo por medio de un haz de ultrasonidos emitidos a través de un aplicador. Estas vibraciones de alta frecuen- cia pasan a través de los tejidos del cuerpo y poco a poco son absorbidas y transformadas en calor.
  • Page 59 FUNCIONAMIENTO Intelect® Legend Series Combo Terapia de combinación En el modo “Combination” (combinación), la terapia de ultrasonido se combina con la terapia “Interferential” (interferencial), “Premodulated” (premodulada) o “High Volt” (alto voltaje) (predeterminada) a fin de generar un efecto terapéutico. En este modo de terapia la superficie de aluminio del aplicador de ultra- sonido pasa a ser la mitad del circuito eléctrico.
  • Page 60 FUNCIONAMIENTO Intelect® Legend Series Combo Varios Para cambiar la configuración predeterminada • Seleccione y modifique el (los) parámetro(s) deseado(s). • Mantenga pulsado el botón (pausar), y a continuación pulse el botón (intro). pause enter Para cambiar el contraste de la pantalla LCD: •...
  • Page 61 Para cumplir plenamente el Título de Reglamentos Federales 21 (21 CFR), esta unidad debe ser recalibrada anualmente. Se recomienda que todos los pro- ductos de ultrasonido Chattanooga sean devueltos a la fábrica o a un distribuidor de servicio autorizado, para su reparación o recalibración. También se recomienda la recalibración después de la sustitución o reparación de cualquiera de los componentes principales.
  • Page 62 Intelect® Legend Series Combo DJO, LLC (la “Compañía”), garantiza que el Intelect Legend Series Combo (el “Producto”) no tiene defectos en materiales ni en mano de obra. Esta garantía permanecerá vigente durante dos años (24 meses) a partir de la fecha de compra del usuario original. Si el producto deja de funcionar durante el período de garantía de dos años debido a un defecto de material o mano de obra, la Compañía o el concesionario (a opción de la Compañía) reparará...
  • Page 63 Moving Rehabilitation Forward™ Certificado ISO 13485 DJO, LLC 1430 Decision St Vista, CA 92081 EE.UU. T: 1-800-592-7329 EE.UU. T: + 1-317-406-2209 F: + 1-317-406-2014 chattgroup.com © 2010 DJO, LLC 28389_C...