Chattanooga Intelect Mobile 2 User Manual

Chattanooga Intelect Mobile 2 User Manual

Electrotherapy
Hide thumbs Also See for Intelect Mobile 2:
Table of Contents

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Chattanooga Intelect Mobile 2

  • Page 2: Table Of Contents

    WAVEFORMS OPERATOR INTERFACE ELECTROTHERAPY PATIENT PREPARATION AND VACUUM MODULE OPERATOR INTERFACE ELECTRODE PLACEMENT INTELECT MOBILE 2 SET COMPONENTS VACUUM ELECTRODE PREPARATION (OPTIONAL) HEAD LEADWIRES | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al...
  • Page 3 CONTENTS DEVICE USER INTERFACE VACUUM MODULE CLEANING CALIBRATION REQUIREMENTS SCREEN DESCRIPTION DEVICE DISPOSAL SETTINGS INSTRUCTION FOR SOFTWARE UPGRADE PRINT SCREEN FUNCTION IFU DOWNLOAD HOME SCREEN INSTALLATION OF BATTERY TREATMENT REVIEW SCREEN REPLACEMENT BATTERY GUIDELINES SCREEN WARRANTY REPAIR/OUT OF WARRANTY REPAIR ELECTROTHERAPY OPERATION WARRANTY START TREATMENT...
  • Page 4: Foreword

    INTRODUCTION FOREWORD INTENDED USE The Intelect Mobile 2 device will be used to deliver a variety This manual is intended for users of Intelect Mobile 2 . It ® of modalities to the patient, Ultrasound and electrical contains general information on operation, precautionary stimulation delivered either as stand alone therapies or in practices, and maintenance.
  • Page 5: General Terminology

    INTRODUCTION GENERAL TERMINOLOGY The following are definitions for the terminology used throughout this manual . Study these terms to become familiar with them for ease of system operation and control functionality of the Intelect Mobile 2 . ® SYSTEM SOFTWARE SYMBOLS Home Run again Back to previous screen...
  • Page 6: Description Of Device Markings

    INTRODUCTION DESCRIPTION OF DEVICE MARKINGS The markings on the unit are assurance of its conformity to the highest applicable standards of medical equipment safety and electromagnetic compatibility and conform to ISO 7010 and ISO15-223-1 One or more of the following markings may appear on the device: Refer to Instructional Manual Booklet Atmospheric Pressure Range...
  • Page 7: Electrotherapy Indications

    INDICATIONS FOR USE E L E C T R O T H E R A P Y I N D I C A T I O N S INDICATIONS CONTRAINDICATIONS TENS The Intelect Mobile 2 should NOT be used under the ®...
  • Page 8: Additional Precautions

    INDICATIONS FOR USE E L E C T R O T H E R A P Y I N D I C A T I O N S ( C O N T I N U E D ) ADDITIONAL PRECAUTIONS ADVERSE EFFECTS •...
  • Page 9: Product Description

    DEVICE DESCRIPTION PRODUCT DESCRIPTION BATTERY MODULE (optional) The Intelect Mobile 2 Electrotherapy is an electrotherapy ® system used with or without an optional Cart, allowing for the inclusion of a Vacuum module. This equipment is to be used only under the prescription and supervision of a licensed medical practitioner.
  • Page 10: Operator Interface

    DEVICE DESCRIPTION OPERATOR INTERFACE The Intelect Mobile 2 Electrotherapy Operator Interface ON/OFF switch (only active when ® contains all the functions and controls necessary for connected to the mains) operator access to all operator utilities, modalities, and Mains power connector parameters for modification and system set up.
  • Page 11: Vacuum Module Operator Interface

    DEVICE DESCRIPTION VACUUM MODULE OPERATOR INTERFACE Resevoir Channel 1 device connection to vacuum Channel 2 device connection to vacuum +/- Channel 1 polarity +/- Channel 2 Polarity | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 12 GENERAL WARNINGS AND PRECAUTIONS CAUTION • This unit should be operated at +5°C to +40°C and 15% to 90% Relative Humidity. The unit should be transported and stored at -20°C to +60°C and 10% to 90% Relative Humidity. • Use of parts or materials other than DJO’s can degrade minimum safety. •...
  • Page 13 GENERAL WARNINGS AND PRECAUTIONS WARNING • This device should be used only under the continued supervision of a physician or licensed practitioner. • Contaminated sponges, electrodes, leadwires, and gel can lead to infection. • Use of electrode on multiple patients can lead to infection. •...
  • Page 14 GENERAL WARNINGS AND PRECAUTIONS DANGER • DO NOT connect the unit to an electrical supply without first verifying that the power supply is the correct voltage. Incorrect voltage may cause unit damage, malfunction, electrical shock, fire, or personal injury. Your unit was constructed to operate only on the electrical voltage specified on the Voltage Rating and Serial Number Plate.
  • Page 15: Intelect Mobile 2 Set Components

    15-0133 INTELECT MOBILE 2 COMBO below. 79967 Carbon electrodes 70010 STIM lead wires 15-1200 Intelect Mobile 2 Ultrasound INTL Set EU Plug 6522055 Chattanooga straps 42198 Electrodes gel 15-1201 Intelect Mobile 2 Ultrasound INTL Set All Plug 15-0144/46/47 Power cord...
  • Page 16: Head To Cart Fixation

    SETUP INSTRUCTIONS HEAD TO CART FIXATION The optional Therapy System Cart, is designed for use with the Intelect Mobile 2 only and allows the user to easily ® transport the System from patient to patient within the clinic as well as store all necessary accessories, supplies, and applicators used for the various modalities of the System.
  • Page 17: Connecting Cables And Inserting Plugs

    3. Complete the registration form to be informed about new product software version availability and IFU updates. 4. Go to documents tab 5. Click on the latest version of your Intelect Mobile 2 device (COMBO, US or STIM) User manual to download POWERING UP THE DEVICE...
  • Page 18: Device Connected To The Mains

    SETUP INSTRUCTIONS DEVICE CONNECTED TO THE MAINS STOP TREATMENT AND TURN OFF THE DEVICE 1. Plug the Power cord into the back of device. Plug the Press Play/pause button to pause treatment then press stop other end of the cord into an electrical outlet. on touch screen.
  • Page 19: Device Light Indicators

    SETUP INSTRUCTIONS D E V I C E L I G H T I N D I C A T O R S Intelect Mobile 2 ELECTROTHERAPY has several light indicators: FRONT PANEL INDICATORS: 1. Colors: • Dark blue indicator around Electrostimulation Channel 1 •...
  • Page 20: System Specifications And Dimensions

    SYSTEM SYSTEM SPECIFICATIONS AND DIMENSIONS Width Depth Height Weight (no battery) Intelect Mobile 2 Head Unit STIM 25.5cm 35.5cm 15cm 2.9kg Cart configurations Cart (Safe working load 6.5kg) 48cm (MAX) 52cm (MAX) 96cm 10.1kg 11.5 Cart with vacuum 48cm (MAX)
  • Page 21: General System Operating And Storage Temperature

    50kPa to 106kPa - Effective radiated power: +6dBm Time required for the Intelect Mobile 2 to warm from the minimum storage temperature between uses until the Intelect Mobile 2 is ready for its INTENDED USE when the ambient temperature is 20 °C: 5h...
  • Page 22: Waveforms

    SYSTEM WAVEFORMS Advice on size and type of electrodes to be used is given in device GUI treatment guidelines. For additional information on Waveforms and output energy, refer to APPENDIX 3 on page 88. CC: Constant Current CV: Constant Voltage IFC (Interferential) Traditional (4 Pole) TENS- Asymmetrical Biphasic Advice on size and type of electrodes to be used is given in device GUI "treatment guidelines"...
  • Page 23 SYSTEM WAVEFORMS (CONTINUED) TENS- Symmetrical Biphasic ™ Advice on size and type of electrodes to be used is given in device GUI "treatment guidelines" feature Advice on size and type of electrodes to be used is given in device GUI "treatment guidelines" feature VMS is a symmetrical biphasic waveform with a 100 µsec interphase interval.
  • Page 24 SYSTEM WAVEFORMS (CONTINUED) IFC Premodulated (Traditional 2 Pole) High Voltage Pulsed Current (HVPC) Advice on size and type of electrodes to be used is given in device GUI "treatment guidelines" feature Advice on size and type of electrodes to be used is given in device GUI "treatment guidelines" feature Premodulated Current is a medium frequency waveform.
  • Page 25: Electrotherapy Patient Preparation And Electrode Placement

    PATIENT PREPARATION ELECTROTHERAPY PATIENT PREPARATION AND ELECTRODE PLACEMENT DURA-STICK Electrode Instructions • Examine the skin for any wounds and clean the skin. ® • Apply the electrodes to the treatment area. Connecting Lead Wires • Ensure the electrodes are applied securely to the skin. Insert the lead with the Red (+) electrode connector into •...
  • Page 26: Vacuum Electrode Preparation (Optional)

    PATIENT PREPARATION VACUUM ELECTRODE PREPARATION (OPTIONNAL) Electrodes Select the prescribed Vacuum Electrode size and install one to the opposite end of each Vacuum lead hose. DJO Vacuum Electrodes are designed specifically for The CORRECT connection, showing a SNUG fit of the leads, optimal use with the Intelect Mobile 2 Vacuum Module.
  • Page 27 PATIENT PREPARATION Place one sponge inside each Vacuum electrode cup. Select “Vacuum” on the treatment review screen. Select “ON” on the vacuum settings screen as indicated in the images below Select Vacuum Mode: In continuous mode, the vacuum unit will maintain the desired vacuum pressure. In the pulsed mode, the vacuum pressure will fluctuate between a high and low pressure level.
  • Page 28: Device User Interface

    USER INTERFACE D E V I C E U S E R I N T E R F A C E SCREEN DESCRIPTION 1. Menu Bar 2. Main Area 3. Channel Bar Each screen contains the following areas: Menu Bar Located at the top of each screen and lists the current screen name.
  • Page 29 USER INTERFACE Main area Located under the menu bar, this area displays icons unique to the current screen. 1. Menu Bar 2. Main Area 3. Channel Bar | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 30 USER INTERFACE Channel Bar Located at the bottom of each screen, this area displays the status information about each channel. When starting a treatment, channels are automatically assigned to the next available channel. Manual selection is done by touching the desired channel. Ultrasound status box Stim Ch 1 status box Stim Ch 2 status box...
  • Page 31: Settings

    USER INTERFACE SETTINGS The settings icon on the top right hand corner of the home screen menu bar (see page 34) offers users the opportunity to set preferences and can be accessed by pressing the '' button. Swipe vertically to see more settings On the home screen, the "current screen name"...
  • Page 32: Print Screen Function

    USER INTERFACE PRINT SCREEN FUNCTION The Intelect Mobile 2 device has a built in function allowing the user to print screen fro example to print a treatment session this performed by: » 1. insert USB drive into the USB port on the back of the Mobile 2 device »...
  • Page 33: Treatment Review Screen

    USER INTERFACE TREATMENT REVIEW SCREEN The Intelect Mobile 2 Treatment Review screens for Electrotherapy include the following information: ® 1. Touch to activate Electrode Placement 2. Adjust with Guidelines Adjustment dial: • Clockwise – Save/Overwrite default Increase settings or Custom Protocols •...
  • Page 34 USER INTERFACE Intensity management in dual channel • Intensity of each channel can be managed individually by simply touching the box to activate it • If treatment offers the possibility to manage both channel intensities together, a "+" symbol appears in the channel intensity box •...
  • Page 35: Guidelines Screen

    USER INTERFACE GUIDELINES SCREEN The Guidelines for electrotherapy provides the following information: Instructions for optimal electrode placement at the left side of the screen. Images illustrating electrode placement and/or US treatment area and recommended applicator choice at the right side of the screen.
  • Page 36: Electrotherapy Operation

    USER INTERFACE ELECTROTHERAPY OPERATION Complete the following steps to begin Electrotherapy treatment: 1. Prepare patient and therapy system for Electrotherapy. Refer to the PATIENT PREPARATION section on page... for electrode selection, preparing the patient, and securing electrodes. 2. Select ELECTROTHERAPY icon from the home screen | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 37 USER INTERFACE 3. Select desired waveform Touch to select Swipe horizontally to see more Note: Refer to the System Specifications section of this manual for all waveform specifications for the Intelect Mobile 2. ® 4. SET UP TREATMENT On the treatment review screen - you can adjust treatment parameters to desired level. Refer to page …...
  • Page 38: Start Treatment

    USER INTERFACE 5. START TREATMENT Press the start/pause button 7. PAUSE TREATMENT Press the Start/Pause button | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 39 USER INTERFACE Pausing treatment will automatically display stop treatment button on the Treatment Review screen To resume treatment, press the Start /Pause button again Note: Pause applies to the selected channel only 8. STOP TREATMENT First pause treatment by pressing the Start/Pause button | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 40 USER INTERFACE Then press the ‘Stop treatment‘ button on the Treatment Review screen. When treatment has completed, the Treatment Summary screen will appear with the following options: • Repeat the treatment by pressing the Run again box. • Save » the treatment protocol to the Custom Protocols (cfr. Page..) •...
  • Page 41: Vacuum Operation

    USER INTERFACE VACUUM OPERATION Complete the following steps to begin Electrotherapy with Vacuum treatment: 1. Prepare patient and therapy system for Vacuum Electrotherapy. Refer to the PATIENT PREPARATION section on page... for electrode selection, preparing the patient, and securing electrodes. 2.
  • Page 42 USER INTERFACE 4. The Treatment Review Screen appears. Refer to pages … for detailed description of the Treatment Review Screen Swipe vertically to see Vacuum box Touch to select | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 43 USER INTERFACE 5. Review the settings on the Vacuum Submenu and adjust accordingly. Activate vacuum Desactivate vacuum Vacuum parameters 1. Touch to activate Active box = green 2. Adjust with Adjustment dial: • Clockwise – Increase Pulsed mode • Counterclockwise – Decrease parameters Vacuum Mode: Continuous: Vacuum unit maintains the desired vacuum pressure.
  • Page 44: Sps (Suggested Parameter Setup)

    USER INTERFACE SPS (SUGGESTED PARAMETER SETUP) The Intelect Mobile 2 has a Suggested Parameter Setup (SPS) icon that is a series of protocol presets where the body area, ® clinical indication, pathological condition and severity are selected by the user, and the suggested algorithm will select the parameter settings.
  • Page 45 USER INTERFACE 3. Select INDICATION Touch to select Swipe vertically to see more 4. Select specification Touch to select | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 46 USER INTERFACE 5. Select MODALITY/WAVEFORM Touch to select Selection refinement summary 6. SET UP TREATMENT On the treatment review screen the suggested treatment settings are displayed and you can adjust parameters to desired level. Refer to page … for detailed description of the Treatment Review Screen. Note: Never start with intensity adjustment –...
  • Page 47 USER INTERFACE 7. START TREATMENT Press the START button | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 48: Treatment Data

    USER INTERFACE TREATMENT DATA After a treatment has been completed, Treatment data can be saved on the Intelect Mobile 2 for later use on the unit. SAVE TREATMENT DATA Click on Assign To button. Treatment data can be assigned to a folder at any time of the treatment (set up, running or...
  • Page 49 USER INTERFACE SAVE TREATMENT DATA TO A NEW ID: Enter ID and Save VIEW AND MANAGE TREATMENT DATA Press the TREATMENT DATA ICON on the home screen | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 50 USER INTERFACE 1. VIEW Treatment Data Select desired ID folder The TREATMENT HISTORY is displayed including all previously saved treatment sessions ranked chronologically Select session to view Treatment Summary for that session. | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 51 USER INTERFACE 2. DELETE Treatment Data Delete all IDs Delete one ID | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 52 USER INTERFACE Delete all treatment sessions Delete one session | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 53: Custom Protocols

    USER INTERFACE CUSTOM PROTOCOLS The Intelect Mobile 2 allows for a maximum of 25 custom protocols to be defined. ® SAVE A CUSTOMIZED PROTOCOL A new custom protocol may be saved at any time using SAVE button 1. Touch SAVE on the TREATMENT REVIEW or TREATMENT SUMMARY screen 2.
  • Page 54 USER INTERFACE 3. The Custom Protocol library is displayed where you can save the protocol as NEW custom protocol or OVERWRITE an existing custom protocol Create new custom protocol Select and overwrite existing protocol Alphabetical list Swipe to see more CREATE NEW CUSTOM PROTOCOL: Enter Custom Protocol Name and Save | In telect...
  • Page 55 USER INTERFACE VIEW AND MANAGE CUSTOM PROTOCOLS Touch the CUSTOM PROTOCOLS icon on the Home Screen 1. VIEW Custom Protocol Select desired Custom Protocol | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 56 USER INTERFACE The TREATMENT REVIEW SCREEN is displayed showing the protocol settings. Start treatment or perform other actions as described in the Electrotherapy operations section. 2. DELETE custom protocol Delete all protocols | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 57: Short Cuts

    USER INTERFACE SHORT CUTS Intelect Mobile 2 allows for 12 custom protocol shortcut assignments on the home screen. ASSIGN SHORTCUT Complete the following steps to assign a home screen shortcut. Unassigned Shortcut icons appear grey in colour: Press one of the unassigned “Shortcut”...
  • Page 58 USER INTERFACE Shortcut assigned on Home screen Once assigned the shortcut icon becomes the colour associated with the modality it contains | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 59: Unassign Short Cut

    USER INTERFACE UNASSIGN SHORT CUT Complete the following steps to unassign a Home screen shortcut for a customized protocol: From the Home screen, press and hold the shortcut icon you wish to unassign. The unit will display a text box asking, “Remove “My Custom Protocol 1” shortcut?” Select “No”...
  • Page 60: Clinical Resources

    USER INTERFACE CLINICAL RESOURCES The Intelect Mobile 2 contains a unique Clinical Resources Library . ® The anatomical and pathological image library are designed to aid the operator in visually understanding and locating specific muscle groups and commonly found problems associated with pathological conditions, as well as providing an educational tool for the clinician to use with the patient.
  • Page 61 USER INTERFACE 2. Touch the body part for which you wish to view information. Choose either anterior (on left of screen) or posterior (on right of screen). 3. The available images for the selected body part are displayed. Touch the image you want to see in full screen mode. | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 62 USER INTERFACE 4. Full screen image Close full screen mode | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 63: Modality/Waveform Descriptions

    USER INTERFACE MODALITY/WAVEFORM DESCRIPTIONS Complete the following steps to view the ultrasound or waveform descriptions: 1. Press the Electrotherapy Waveform description icon on the Clinical Resources screen 2. Select the desired waveform (in case of Electrotherapy Waveform description) | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 64 USER INTERFACE 3. The modality or waveform description is displayed | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 65: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING 1. All system messages, warning messages and fault messages that are generated by the device are self-explanatory excepting system error. 2. If System error occurs, note error code and contact DJO selling dealer or DJO Service Department. | In telect M o b il e 2 E L E C T R O T H E R A P Y U ser Manu al ®...
  • Page 66: Replacement Accessories

    ACCESSORIES R E P L A C E M E N T A C C E S S O R I E S The following provides users of the Intelect Mobile 2 the necessary information to order replacement accessories used with the ®...
  • Page 67: Electrotherapy Accessories

    ACCESSORIES ELECTROTHERAPY ACCESSORIES Model Number Description 6522055 Chattanooga Strap 79967 6 x 8 cm (2.5 x 3”) carbon electrodes (4x) GENERAL ACCESSORIES Model Number Description 15-1136 Mobile 2 Cart 15-1137 Cart with Vacuum 79977 HIGHVOLT PROBE KIT- Includes Probe and Sponge Applicator Tips (15 and 8 mm) 114.610exp...
  • Page 68: Vacuum Accessories

    ACCESSORIES VACUUM ACCESSORIES Model Number Description 70030 LEADHOSEVACUUM CH 1/2 KIT 70032 LEADHOSEVACUUM CH 1/2 KIT XL 70034 90mm VACUUM ELECTRODE KIT 70035 60mm VACUUM ELECTRODE KIT 70036 30mm VACUUM ELECTRODE KIT 70037 90mm VACUUM SPONGE KIT 70038 60mm VACUUM SPONGE KIT 70039 30mm VACUUM SPONGE KIT 70040...
  • Page 69: Vacuum Module Cleaning

    MAINTENANCE CLEANING THE INTELECT MOBILE 2 Flushing Lead Hoses and Reservoir ® Connect all two lead hoses to the Vacuum Module. With the system disconnected from the power source, clean Submerse the other end of the lead hoses into a the system with a clean, lint-free cloth moistened with container filled with at least 250 ml (8 fl oz) of hot water water and mild antibacterial soap.
  • Page 70: Calibration Requirements

    MAINTENANCE CALIBRATION REQUIREMENTS Go to documents tab Click on the latest version of your Intelect Mobile 2 The unit was calibrated during the manufacturing process device (COMBO, US or STIM) User manual to download and doesn't need calibration during the product life.
  • Page 71: Warranty Repair/Out Of Warranty Repair

    SERVICE AND WARRANTY WARRANTY REPAIR/OUT OF WARRANTY REPAIR Service When the Intelect Mobile 2 or any accessories require ® service, contact the selling dealer or DJO Service Department. All Therapy Systems and accessories returned to the factory for service must include the following: Written statement containing the following information: •...
  • Page 72: Warranty

    SERVICE AND WARRANTY WARRANTY This Warranty Does Not Cover: • Replacement parts or labor furnished by anyone other DJO, LLC (“Company”) warrants that the Intelect Mobile ® than the Company, the selling dealer or a Company 2 and Vacuum Module (“Products”) are free of defects in service technician material and workmanship.
  • Page 73: Electromagnetic Compatibility (Emc)

    APPENDIX ELECTROMAGNETIC COMPATIBILITY Information Report (TIR) 18, Guidance on Electromagnetic Compatibility of Medical Devices (EMC) for Clinical/Biomedical Engineers. AAMI TIR 18-1997. The Intelect Mobile 2 has been tested and found to comply ® Arlington, Virginia: Association for the Advancement of with the electromagnetic compatibility (EMC) limits for Medical Instrumentation;...
  • Page 74 APPENDIX ELECTROMAGNETIC COMPATIBILITY (EMC) TABLES Guidance and Manufacturer’s Declaration - Electromagnetic Emissions The Intelect Mobile 2 is intended for use in the electromagnetic environment specified below. ® The customer or the user of the Intelect Mobile 2 should assure that it is used in such an environment. ®...
  • Page 75 APPENDIX ELECTROMAGNETIC COMPATIBILITY (EMC) TABLES (CONTINUED) Guidance and Manufacturer’s Declaration - Electromagnetic Immunity The Intelect Mobile 2 is intended for use in the electromagnetic environment specified below. ® The customer or the user of the Intelect Mobile 2 should assure that it is used in such an environment. ®...
  • Page 76 APPENDIX ELECTROMAGNETIC COMPATIBILITY (EMC) TABLES (CONTINUED) Guidance and Manufacturer’s Declaration - Electromagnetic Immunity The Intelect Mobile 2 is intended for use in the electromagnetic environment specified below. ® The customer or the user of the Intelect Mobile 2 should assure that it is used in such an environment. ®...
  • Page 77 APPENDIX ELECTROMAGNETIC COMPATIBILITY (EMC) TABLES (CONTINUED) Recommended separation distances between portable and mobile RF communications equipment and the Intelect Mobile 2 ® The Intelect Mobile 2 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Intelect ®...
  • Page 78 DJO France SAS Centre Européen de Frêt 3 rue de Bethar 64990 Mouguerre • France T: + 33 (0) 5 59 52 86 90 • F: + 33 (0) 5 59 52 86 91 DJOglobal.com DJO, LLC | 1430 Decision Street | Vista | CA 92081-8553 | U.S.A. www.DJOglobal.com...