21.2)
REMOVAL OF SPARK ELECTRODE/FLAME SENSOR
1. Remove the glass panel as shown in Section 21.1). Open the access panel assembly by loosening the
screws.
2. Disconnect the ignition cable and flame sensor wires (not shown) from the spark electrode/flame sensor.
3. Remove the screws holding the assembly and slide the spark electrode/flame sensor away from the
heater.
4. Inspect the ceramic portion of the electrode/flame senors for any cracks. Remove any foreign matter from
the electrode tips and check that the spark gap is 5.0mm (.199"). If the electrode/flame sensor rods are
badly oxidized, replace the electrode/flame sensor in the reverse order.
21.3)
REMOVAL OF MAIN BURNER ORIFICE (INJECTOR)
1. Open the access panel assembly as shown in Section 21.2). Note: This is removed from the illustration for
clarity. Unscrew the main burner orifice from the gas valve manifold using a 13mm (½") end wrench.
2. Inspect the orifice and clean as necessary with a soft bristle brush.
DO NOT DAMAGE ORIFICE OPENING BY USE OF SOLID OBJECTS.
Form 44201360
Oct 2019
41
Need help?
Do you have a question about the COLD BLOCKER WB10CE-N7 and is the answer not in the manual?
Questions and answers