14.0)

INSTALLATION OF THE CERAMIC GLASS

Only install the ceramic glass once the heater has been attached to a suitable gas (see Section 15.0), electrical
supply (see Section 16.0) and has been commissioned (see Section 18.0).
Read this section to the end to avoid glass breakage.
1. Locate the "Glass Access Retainer" and carefully remove with a suitable Phillips screw driver the two (2)
black oxide sheet metal screws holding it in place. Retain screws and Glass Access Retainer for later.
2. The side of the glass where the logo is attached must be slid in first for the logo's final position to be at the
control side of the heater.
3. Slide the glass into the "Glass Retainer Rails". The glass must be held parallel to the Glass Retainer Rails
during assembly. The glass will slide in easy with ample clearance. Slide the glass until it is positioned
under the Glass Retainer at the heaters control enclosure side. At this point the glass will be flush with the
heater at the insertion point.
Note: If the ceramic glass does not slide in easily review position of ceramic glass to glass retainers and
adjust if needed. Do not force the ceramic glass into the glass retainers!
4. Reinstall the Glass Access Retainer removed in 1. with the two (2) sheet metal screws.
Form 44201360