TYPICAL HEATER LAYOUTS

The diagram below shows the recommended spacing layout between heaters.
Dimension
A. Mounting Height
B. Distance to the end of the
patio
C. Distance between heaters.
D. Distance between heaters*
*Note the distance D for angled heaters applies when they are facing towards each other.
Below are examples of patio heating applications.
Form 44201360
Oct 2019
Horizontal
Min.
Max.
2.4m
3.4m
0m
1.8m
2.4m
3.7m
2.4m
4.9m
14
15 to 30 degree angle
Min.
Max.
2.15m
2.7m
0m
1.8m
2.15m
3.4m
2.4m
5.5m
Above 30 degree angle
Min.
Max.
2.15m
2.4m
0m
1.8m
1.8m
3.0m
2.4m
4.9m