Command:
AA 05 05 74 93
Response:
Leader
Len
AA
7
Example Response:
AA 07 05
Where the firmware version returned is:

5.2.2.6 Setup (0x06)

The Setup command requests the STINGR to use the specified setup parameters. These are stored in non-volatile
memory.
0x06
Command:
header len 04
RESERVED
AA
0E 06 XX XX XX XX
Where:
RF channel :
# of bursts:
Minimum Burst Interval:
Maximum Burst Interval:
Example Command:
AA 0E 06 00 00 00 00
Where the setup information is:
RF channel :
# of bursts:
Minimum Burst Interval:
Maximum Burst Interval:

5.2.2.7 Query Setup (0x07)

The Query Setup command requests the STINGR to return the current setup parameters.
Revision 1.0
09/30/15
Revision 1.0
4
FW major
FW minor
5
XX
XX
01 07
E0 6A
1.7
RF channel # of Bursts Interval Min Interval Max RESERVED CRC1 CRC2
XX
XX
Valid values are: 0 = Channel A, 1 = Channel B, 2 = Channel C, 3 = Channel D
Valid values are: 0x01 thru x14 (1 to 20 bursts)
Units of 5 seconds. Valid values are: 0x01 thru 0x3C (5 to 300 seconds)
Units of 5 seconds. Valid values are: 0x02 thru 0x78 (10 to 600 seconds)
00 03 18 30
00
Channel A
03
3 bursts per message
18
0x18 = 24, 24 x 5 = 120 seconds
30
0x30 = 48, 48 x 5 = 240 seconds
Subject To Change without Notice
STINGR Users Manual
CRC1
CRC2
CC
CC
XX
XX
00 CE 9C
XX
CC
CC