Changes And Alterations To The Equipment; Responsibility Of The Operating Entity; Personnel Requirements; Work Safety - Eaton US-S ESF30 Series Mounting And Operating Instructions

Fire-resistant cabinet
Hide thumbs Also See for US-S ESF30 Series:
Table of Contents

Advertisement

instructions before commencing work on the equipment.
This also applies if the person concerned has worked with
the same or similar equipment in the past or was trained by
the manufacturer.
2.3 Changes and alterations to the equip-
ment
In order to avoid hazards and to ensure the best possible
performance, no modifications, retrofits and add-ons are
permitted on the equipment unless these were expressly
approved by the manufacturer.

2.4 Responsibility of the operating entity

These operating instructions must be kept in the direct
vicinity of the equipment and must always be accessible to
people working on or with the equipment. The equipment
must only be operated if it is in an exemplary and operationally
safe condition. The equipment must be checked every time
before it is put into operation. The operating instructions as
set out in the manual must be complied with in full!

2.5 Personnel requirements

Only authorised and qualified personnel may carry out
work on or with the device. These personnel must have

3 Technical Data

Tabelle 1: Technical Data
US-S ESF30
Type
28-P
Approvals / Certificates
DIBT
Fire exposure from out-
30
side (min)
Enclosure specifications
Enclosure
Fibre plates
Protection rating
IP42
Protection class
l
Dimensions
2064 x 914 x 604
(W x H x D in mm)
Weight (kg) empty cabinet 330
Closure
Sash fastener
Electronic specifications
Rated voltage
400 V 50 Hz
Number of module slots
30
Max. conductor size /
4
final circuits (mm²)
Max. conductor size (mm²) 35
Max. total conductor
775
size (mm²)
Mounting and Operating Instructions Fire-Resistant Cabinet Type US-S ESF30 40071860245 (B) February 2020 www.ceag.de
been trained in possible hazards that may occur. A qualified
person is anyone who, based on his/her training, expertise
and experience as well as his/her knowledge of the relevant
provisions, is able to assess the work that he/she has been
given and to identify any potential hazards.

2.6 Work safety

Following the safety information and instructions provided in
this operating manual is essential to avoid bodily injuries and
property damage while working on and with the equipment.
US-S ESF30
US-S ESF30
13-P
SOU5
DIBT
VDE
30
30
Fibre plates
External fibre
plates / Internal
plastic
IP42
IP65
l
l
1198 x 898 x 449
1140 x 400 x 230
187
81
Sash fastener
Sash fastener
230 V 50 Hz
230 V 50 Hz
13
5
4
4
35
10
625
89
US-S ESF30
US-S ESF30
SOU3
SOU2
VDE
VDE
30
30
External fibre
External fibre
plates / Internal
plates / Internal
plastic
plastic
IP65
IP65
l
l
840 x 400 x 230
690 x 400 x 230
61
51
Sash fastener
Sash fastener
230 V 50 Hz
230 V 50 Hz
3
2
4
4
10
10
79
74
2 Safety
US-S ESF30
SOU1
VDE
30
External fibre
plates / Internal
plastic
IP65
I
535 x 396 x 230
35
Sash fastener
230 V 50 Hz
1
4
10
39
5

Advertisement

Table of Contents
loading

Table of Contents