Application Logic Cfc; Diagnosis - Siemens SIPROTEC4 7SJ61 Protocol Manual

Communication module profibus-dp bus mapping
Hide thumbs Also See for SIPROTEC4 7SJ61:
Table of Contents

Advertisement

Offset
Designation of the
SIPROTEC objects
2/3
Input channel 3 (UsrSpO/O11)
2/4
Input channel 4 (UsrSpO/O12)
2/5
Input channel 5 (UsrSpO/O13)
2/6
Input channel 6 (UsrSpO/O14)
2/7
Input channel 7 (UsrSpO/O32)
3.2.1.4

Application logic CFC

Ref. to chap. 1.6 for additional notes.
Offset
Designation of the
SIPROTEC objects
3/0
CFC-Output indication 1
(UsCfcSpO1)
3/1
CFC-Output indication 2
(UsCfcSpO2)
3/2
CFC-Output indication 3
(UsCfcSpO3)
3/3
CFC-Output indication 4
(UsCfcSpO4)
3/4
CFC-Output indication 5
(UsCfcSpO5)
3/5
CFC-Output indication 6
(UsCfcSpO6)
3/6
CFC-Output indication 7
(UsCfcSpO7)
3/7
CFC-Output indication 8
(UsCfcSpO8)
4/0
CFC-Output indication 9
(UsCfcSpO9)
4/1
CFC-Output indication 10
(UsCfcSpO10)
4/2
CFC-Output indication 11
(UsCfcSpO11)
4/3
CFC-Output indication 12
(UsCfcSpO12)
4/4
CFC-Output indication 13
(UsCfcSpO13)
4/5
CFC-Output indication 14
(UsCfcSpO14)
4/6
CFC-Output indication 15
(UsCfcSpO15)
4/7
CFC-Output indication 16
(UsCfcSpO16)
3.2.1.5

Diagnosis

Ref. to chap. 1.5.5 and 1.5.6 for additional notes regarding "Error with a summary alarm" and "Alarm summary
event".
Offset
Designation of the
SIPROTEC objects
5/0
Device OK
5/1
ProtActive
5/2
Settings Calc.
5/3
Error Sum Alarm
7SJ61...7SJ63, 7SJ65, 6MD63 PROFIBUS-DP – Bus mapping
C53000-L1840-B006-02
Comments
Single-point indication ON/OFF
Single-point indication ON/OFF
Single-point indication ON/OFF
Single-point indication ON/OFF
Tagging / Internal single-point indication ON/OFF
Comments
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Single-point indication ON/OFF,
released as CFC output
Comments
1 = Update of the device replica in the SIPROTEC
device completed after initial start or restart
1 = At least one protection function is active
1 = Setting calculation is running
1 = Error with a summary alarm ON
Standard mapping 2-2
Internal
object no.
Internal
object no.
Internal
object no.
51
52
70
140
3-5