8

CLEANING THE UNIT

A clean state is the best method of ensuring operation with-
out problems. After you have finished spraying, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit. The cleaning agent used for cleaning (only
with a flash point above 21 °C) must be suitable for the coat-
ing material used.
Warm water improves the cleaning effect in
the case of water-dilutable coating materials.
Secure the spray gun, refer to the operating manual of
the spray gun.
Remove and clean the tip.
Unit with suction system
1. Open the relief valve, valve setting
switch on the device.
2. Remove the suction system from the material container,
the return tube remains over the material container.
3. Immerse the suction system into a container filled with a
suitable cleaning agent
4. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
5. Close the relief valve, valve setting
With coating materials containing solvents,
an earthed metal container must be used
for cleaning into which the cleaning agent is
pumped.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
6. Pull the trigger guard of the spray gun in order to pump
the remaining coating material from the suction hose,
high-pressure hose and the spray gun into an open con-
tainer (if appropriate, increase the pressure at the pres-
sure control valve slowly in order to obtain a higher mate-
rial flow).
7. Open the relief valve, valve setting
8. Pump suitable cleaning agent in the circuit for several
minutes.
The cleaning effect is increased by alterna-
tively opening and closing the spray gun.
9. Close the relief valve, valve setting
10. Pump the remaining cleaning agent into an open contain-
er until the pump is empty.
11. Switch off the unit
1. Open the relief valve, valve setting
2. Turn the pressure control valve back in order to set a mini-
3. Close the relief valve, valve setting
(circulation) and
4. Pull the trigger guard of the spray gun in order to pump
5. Fill up hopper with suitable cleaning agent.
6. Open the relief valve, valve setting
7. Pump suitable cleaning agent in the circuit for several
(spraying).
8. Close the relief valve, valve setting
9. Pump the remaining cleaning agent from the hopper,
10. Open the relief valve, valve setting
(circulation).
(spraying).
DISPLAYS AT THE UNIT / CLEANING THE UNIT
Unit with upper hopper
mal spraying pressure.
With coating materials containing solvents,
an earthed metal container must be used
for cleaning into which the cleaning agent is
pumped.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
the remaining coating material from the hopper, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).
minutes.
The 20 l top container can be easily removed
and emptied after cleaning.
high-pressure hose and the spray gun into an open con-
tainer.
switch off the device.
GB
(circulation).
(spraying).
(circulation).
(spraying).
(circulation) and
49