Table of Contents

Advertisement

PCBs

4. PCBs
Warning
Step
1
Remove the screw.
2
Unfasten the 2 hooks
and remove the
electrical box cover.
3
Disconnect the 3
connectors from the
terminal strip.
4
Remove the earth/
ground screw (upper).
5
Cut the 2 clamps.
10
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Top view
Electrical box cover
Hook
Hole
Terminal strip
Bottom view
Clamp
Hook
(R23717)
Earth/ground screw (upper)
HL1
HN1
S
(R24358)
(R23720)
Si001658EA
Points
The locations of the hooks
are indicated with
mark
on the electrical box cover.
When reassembling, make
sure that the 2 hooks are
securely fastened.
When reassembling, put all
the wires through the hole of
the electrical box.
[HL1] [HN1] [S]: terminal strip
HN1 (white)
HL1 (black)
S (red)
Removal Procedure
(R23719)