Thermistor Assy - Daikin RKC18QV2S Service Manual

Table of Contents

Advertisement

Thermistor ASSY

5. Thermistor ASSY
Warning
Step
1
Pull out the outdoor
temperature thermistor
holder and release the
thermistor wire from the
slit.
2
Remove the 5 screws.
3
Lift up the right side
panel to unfasten the 2
hooks.
4
Remove the right side
panel.
5
Cut the clamp.
6
Pull out the outdoor
heat exchanger
thermistor.
12
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Back view
Slit
Hook
Clamp
Thermistor wire
Outdoor temperature
thermistor holder
Right side panel
Outdoor heat
exchanger
thermistor
Points
When reassembling, pass
the outdoor temperature
thermistor through the top U-
bend of the outdoor heat
exchanger.
(R23724)
When reassembling, make
sure that the 2 hooks are
securely fastened.
Some models do not have
the clamp.
(R23725)
The location of the outdoor
heat exchanger thermistor
varies depending on the
model.
Be careful not to lose the clip
for the thermistor.
(R23726)
Removal Procedure
Si001658EA
(R20243)
Clip
(R3264)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents