Daikin RKC18QV2S Service Manual page 7

Table of Contents

Advertisement

Si001658EA
Step
4
Remove the nut, and
then the outdoor fan.
5
Remove the screw of
the fan motor fixing
frame.
6
Unfasten the 2 hooks at
the bottom and remove
the fan motor fixing
frame.
7
Open the 2 hooks and
release the fan motor
lead wire.
8
Remove the 4 screws,
and then the fan motor.
Removal Procedure
Procedure
D-cut
Nut
Outdoor fan
Back view
Hook
Front view
Fan motor
(R23702)
Fan motor fixing frame
(R23703)
Fan motor lead wire
(R23704)
(R24357)
Outdoor Fan / Fan Motor
Points
Nut size: M6
10 mm
(0.39 inch)
(R18954)
When reassembling, align
the
mark of the fan rotor
with the D-cut section of the
motor shaft.
When reassembling, fit the 2
lower hooks into the bottom
frame.
(R22574)
5

Hide quick links: