Step
2
Remove the protection
bushing.
3
Disconnect the
compressor lead wires
(U, V, W) and the
overload protector.
4
Cut the clamp.
5
Remove the putties.
6
Heat up the brazed part
of the discharge side
pipe and disconnect it.
7
Heat up the brazed part
of the suction side pipe
and disconnect it.
8
Remove the 3 nuts of
the compressor.
9
Lift up the compressor
and remove it.
Removal Procedure
Procedure
Protection bushing
Overload
protector
V (yellow)
Clamp
Brazed part of the
discharge side pipe
Compressor
U (red)
W (blue)
(R23738)
Brazed part of the
suction side pipe
Putty
Nut
(R23743)
Compressor
Points