Outdoor Fan / Fan Motor - Daikin RKC18QV2S Service Manual

Table of Contents

Advertisement

Outdoor Fan / Fan Motor

2. Outdoor Fan / Fan Motor
Warning
Step
1
Cut the clamp and pull
out the sealing material.
2
Disconnect the
connector [S79].
3
Release the fan motor
lead wire from the 2
slits and from the 4
hooks on the electrical
box.
4
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Sealing material
[S79]
Hook
Fan motor lead wire
Clamp
(R23699)
(R23700)
Slit
(R23701)
Si001658EA
Points
[S79]: fan motor
When reassembling, put the
fan motor lead wire through
the back of the fan motor to
avoid any entanglement with
the outdoor fan.
Lead wire
Outdoor fan
(R3249)
Removal Procedure