Omega CN8200 Series User Manual page 22

1/16 din temperature & process controllers
Table of Contents

Advertisement

Technical
Specifications
Operating Limits
Ambient Temperature
Relative Humidity Tolerance 90%, Non-Condensing
Power
Power Consumption
Performance
Accuracy
Setpoint Resolution
Repeatability
Temperature Stability
TC Cold-End Tracking
Noise Rejection
Process Sampling
Control Characteristics
Setpoint Limits
Alarms
Proportional Band
32°F to 140°F (0°C to 60°C)
100 to 250 V
50/60 Hz (Single-Phase)
100 to 250 Vdc
24 Vac/dc
Less than 6 VA
±0.20% of Full Scale
(±0.10% Typical), ±1 Digit
1 Count / 0.1 Count
±1 Count
5 µV /°C (Maximum)
0.05°C /°C Ambient
>100 dB Common Mode,
>70 dB Series Mode
10 Hz (100 ms)
Automatically Adjust to
Selected TC/RTD
Adjustable for High/Low;
Selectable Process, Deviation,
or Band Alarms
1 to Span of Sensor
34
Technical
Specifications
Integral
Derivative
Cycle Time
Control Hysteresis
Autotune
Manual Control
Mechanical Characteristics
Display
Numeric Range
Front-Panel Cutout
Depth Behind Panel
Front Panel Rating
Operating Temperature
Humidity Conditions
Parameter Retention
Connections
Contacts
35
0 to 9600 Seconds
0 to 2400 Seconds
200 ms; 1 to 120 sec
1 to Span of Sensor
Operator Initiated from
Front Panel
Operator Initiated from
Front Panel
Dual, 4-digit 0.36" (9.2 mm)
LED display
Process Value: Orange
Setpoint Value/Menu: Green
-1999 to 9999
1.771" x 1.771"
(45 mm x 45 mm)
3.937" (100 mm)
NEMA 4X
32 to 140° F (0 to 60° C)
90% R.H. max.,
non-condensing
Solid-state, non-volatile
memory
Input and output via barrier
strip with locking terminals
Twin bifurcated

Advertisement

Table of Contents
loading

Table of Contents