Initial Setup
Sequence
4) If manual tuning the controller, set Control Menu
parameters by pressing the Menu Access
IMPORTA NT: Upon
repeatedly until
entering a new value,
Mode/Enter
you MUST either press
selections and the Raise
the Mode/Enter key, the
the appropriate setting. Otherwise, proceed to Step 6.
Menu A ccess key, or
index to a different
5) If autotuning the controller, press and hold the Menu
parameter in order for
Access
the new value to register.
system. Press the Menu Access key repeatedly until the
The controller will NOT
accept new values
Autotune Damping parameter
without a key press.
sure the Damping parameter is set properly (see page 37).
Press and hold the Menu Access
seconds to return to the Process Variable display and
proceed to Step 4 on page 43.
6) Return to Process Variable Display. Press and hold
the Menu Access
to PV display.
7) Adjust setpoint. Use the Raise
enter the desired setpoint. Wait for process to stabilize
before proceeding, e.g., in the case of a heating process,
return to ambient temperature.
8) Security Level. Press and hold the Menu Access key
for approximately 10 seconds until
Using the Raise or Lower keys, set the most restrictive
level suited to your application. See page 16.
key
is displayed. Then, use the
key to index through the available
or Lower
keys to select
key for three seconds to access the menu
is displayed. Make
key for three
key for three seconds to return
or Lower
key to
is displayed.
Menus and Parameter
Descriptions
Input
Display
Output
Control
Alarm
Tune
Recipe
Supervisor
Calibration
Option
Communications
Contact/Digital
Input
Remote Analog
Setpoint
Auxiliary Output
16
17
Menus and Parameters
Used to select sensor-related parameters, such as input type,
limits, and scaling.
Used to set or change decimal position and display units.
Used to specify output usage, control methods, and alarms.
Used to select parameters associated with the control methods.
Used to select alarm parameters .
Note: This menu is also functional for controllers not
equipped with alarm hardware; however, alarm indication
will be only visual via the A1 and A2 LEDs on the front panel.
Used to set the autotune damping parameter.
Used to set ramp and soak parameters.
Used to set fail-safe and supervisory parameters.
Used to recalibrate input.
Used to select installed option.
(Option) Used to set serial communications parameters.
(Option) Used to select switch input functions.
(Option) Used to enter remote analog setpoint parameters.
(Option) Used to set auxiliary output parameters.