Startup Counter For Motor; Startup Supervision Of Motors; Trip Circuit Supervision; Internal Mode Status - Siemens SIPROTEC 7SJ80 Manual

Overcurrent protection, motor protection, voltage and frequency protection
Hide thumbs Also See for SIPROTEC 7SJ80:
Table of Contents

Advertisement

Binary Input Points
Static (Steady-State) Object Number: 1
Change Event Object Number: 2
Request Function Codes supported: 1 (read)
Static Variation reported when variation 0 requested: 1 (Binary Input with status)
Change Event Variation reported when variation 0 requested: 2 (Binary Input Change with Time)
Point
Name
Index
3.2.9

Startup Counter for Motor

57
66 ACTIVE
58
66 TRIP
3.2.10

Startup Supervision of Motors

59
START-SUP ACT
60
START-SUP TRIP
61
START-SUP pu
3.2.11

Trip Circuit Supervision

62
74TC ACTIVE
63
FAIL: Trip cir.
3.2.12

Internal Mode Status

64
Cntrl Auth
65
ModeLOCAL
66
Relay OK
67
Running
68
ProtActive
69
Error Sum Alarm
70
Alarm Sum Event
71
Relay Pickup
72
Relay TRIP
73
Test mode
3.2.13
Control switches return position indication(double point
commands)
74
52 Breaker
75
52 Breaker status
76
Switch 1
77
switch 1 status
78
Switch 2
79
switch 2 status
80
Switch 3
81
switch 3 status
SIPROTEC DNP 3.0 - Bus mapping / Point lists 7SJ80/7SK80/7RW80
C53000-L2040-A320-2
66 Motor start protection ACTIVE; ON = 1, OFF = 0
66 Motor start protection TRIP; ON = 1, OFF = 0
Startup supervision is ACTIVE; ON = 1, OFF = 0
Startup supervision TRIP; ON = 1, OFF = 0
Startup supervision Pickup; ON = 1, OFF = 0
74TC Trip circuit supervision is ACTIVE; ON = 1, OFF = 0
74TCFailure Trip Circuit; ON = 1, OFF = 0
Control Authority; LOCAL=1, REMOTE=0
Control mode LOCAL; UNLOCKED=1, LOCKED=0
Relay OK; ON = 1, OFF = 0
Setting calculation is running; ON = 1, OFF = 0
At least one protection funct. is active; ON=1, OFF=0
Error with a summary alarm; ON = 1, OFF = 0
(ref. to chap. 1.1.1)
Alarm Summary Event; ON = 1, OFF = 0
(ref. to chap. 1.1.2)
Relay Pickup; ON = 1, OFF = 0
General TRIP of the relay; ON = 1
Test mode; ON=1, OFF=0
input state of switch breaker; 0=open, 1=close
switch breaker failure status; 0=switch breaker position is open or close, 1= switch
breaker is in an intermediate position or position state is incorrect.
input state of switch 1; 0=open, 1=close
switch 1 failure status; 0= switch 1 position is open or close, 1= switch 1 is in an in-
termediate position or position state is incorrect.
input state of switch 2; 0=open, 1=close
switch 2 failure status; 0= switch 1 position is open or close, 1= switch 1 is in an in-
termediate position or position state is incorrect.
input state of switch 3; 0=open, 1=close
switch 3 failure status; 0= switch 2 position is open or close, 1= switch 2 is in an in-
termediate position or position state is incorrect.
Description
Binary Input Points
Class
3
2
3
2
2
3
1
3
3
1
3
2
2
2
1
1
3
1
1
1
1
1
1
1
1
27