Page 1
550 ITT 550 ITT 550 ITT 550 ITT 550 ITT 550 ITT 550 ITT 550 ITT 550 ITT 550 ITT ISTRUZIONI PER L’USO - NORME DI INSTALLAZIONE INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION INSTRUCTIONS - REGLES D’INSTALLATION INSTRUCCIONES PARA EL USO - NORMAS PARA LA INSTALACION GEBRAUCHSANLEITUNG - ANWEISUNGEN ZUR INSTALLATION GEBRUIKSAANWIJZINGEN –...
23) Eloigner de la portée des enfants les radiocommandes ou tout autre of danger. générateur d'impulsions, pour éviter tout actionnement involontaire de 6) FAAC declines all liability caused by improper use or use other than that for l'automatisme. which the automated system was intended.
HINWEISE FÜR DEN INSTALLATIONSTECHNIKER 9) FAAC is niet aansprakelijk als de regels der goede techniek niet in acht genomen zijn bij de bouw van het sluitwerk dat gemotoriseerd moet ALLGEMEINE SICHERHEITSVORSCHRIFTEN worden, noch voor vervormingen die zouden kunnen ontstaan bij het 1) ACHTUNG! Um die Sicherheit von Personen zu gewährleisten, sollte die...
• conforms to the essential safety requirements of the following EEC directives: 73/23/EEC and subsequent amendment 93/68/EEC. 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC Additional information: This product underwent a test in a typical, uniform configuration (all products manufactured by FAAC S.p.A.). Bologna, 01-08-2006 The Managing Director A. Bassi Notes on reading the instruction Read this installation manual to the full before you begin installing the product.
CONTROL UNIT 550 ITT The 550 ITT control unit was designed to command the opening of up-and-over doors with one or two motors. Thanks to management by encoder and opening and closing limit-switches, if correctly installed, it can guarantee installation in conformity with current safety regulations.
4. BOARD COMPONENTS ) t i g i l g i l " +" " -" " F" 5. ELECTRICAL CONNECTIONS FSW CL ENCODER FSW OP 11 12 13 14 15 16 PE N L FLASH LAMP 230 V~ 50Hz _ _ + 1 2 3 4 5 6 7 8 9 10 max.
4 = -FSW TX = Negative pole for power supply to photocell transmitters Separate connection of the negative pole of the transmitters makes it possible to use the Failsafe control on the photocells, thus increasing the system's safety level. 5 = FCA = Opening Limit-switch contact (N.C.) The opening limit-switch consists of a micro-pushbutton which, activated by the cam when the door reaches open position, stops movement immediately or, according to programming, after 3 sec.
7. PROGRAMMING To program the operation of the automated system, you must access the "PROGRAMMING" mode. Programming is in two parts: BASIC and ADVANCED. 7.1. BASIC PROGRAMMING To access BASIC PROGRAMMING, use push-button F: • if you press it (and hold it down), the display shows the name of the first function. •...
Page 9
ADVANCED PROGRAMMING Function Display Default PRE-FLASHING of flashing lamp: Can be adjusted from sec. in one second steps. LIMIT-SWITCH INTERVENTION MODE: For setting motor operation when limit-switches (optionals) are reached: =FCA/FCC: Stops immediately =FCA/FCC: Stops after 3 sec. deceleration =FCA: Stops immediately FCC: Stops after 3 sec.
We advise you to adjust the electronic clutch in conformity with current safety regulations. 10. ENCODER OPERATION Thanks to encoder management, the 550 ITT control unit, if correctly installed, guarantees installation in compliance with current safety regulations. The encoder is active during both door opening and closing stages.
Page 12
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...